Greenlee IPM-300 Manual De Instrucciones página 2

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Description
The Greenlee IPM-300 Industrial Process Meter is a hand-held testing device intended to
calibrate equipment with the following inputs or outputs: milliamp, DC voltage, thermocouple,
RTD, and frequency. It also measures AC and DC voltage, ohms, and checks continuity.
The IPM-300 has the ability to:
• Source and read 0.00 mA to 24.0 mA and display current in mA or percent of 4-20 mA
span.
• Simulate a 2-wire transmitter.
• Simultaneously power and measure 2-wire transmitters.
• Calibrate DC millivolt and voltage instrumentation.
• Source and read directly in °C and °F for thermocouple types J, K, T, and E.
• Calibrate RTD in °C or °F using a built-in platinum 100 ohm DIN/IEC 751 table.
• Read and source in ohms.
• Generate zero crossing square waves from 1 Hz to 1000 Hz, 0.01 kHz to 10.00 kHz, and
from 1 CPM to 1000 CPM (counts per minute).
• Function as a frequency counter.
• Check line voltage or mains from 0.0 to 250.0 VAC.
• Locate pairs of wire, open connections, and shorts.
Safety
Safety is essential in the use and maintenance of Greenlee tools and equipment. This
instruction manual and any markings on the tool provide information for avoiding hazards and
unsafe practices related to the use of this tool. Observe all of the safety information provided.
Purpose
This instruction manual is intended to familiarize all personnel with the safe operation and
maintenance procedures for Greenlee IPM-300 Industrial Process Meter.
Keep this manual available to all personnel.
Replacement manuals are available upon request at no charge.
Greenlee and
are registered trademarks of Greenlee Textron.
2
All manuals and user guides at all-guides.com
KEEP THIS MANUAL

Publicidad

Tabla de contenido
loading