Operation

4.1

Switch-on/switch-off

Use the central main switch on the front of the unit
(see fig. 1, item 6) to switch on the EPS 200 / 205.
 After switch-on, the Windows operating system
starts up and then the EPS 200 system software.
Before switching off at the central main switch,
first end the EPS 200 system software and then shut
down the Windows operating system.
i
Prior to renewed switch-on, the EPS 200 / 205 must
have been switched off for at least 60 seconds.
i
Do not switch off the EPS 200 / 205 while com-
ponent testing is in progress (except in the
case of emergency stop). Always switch off the
EPS 200 / 205 by way of the central main switch on
the front of the unit before unplugging the three-
phase AC connector.
4.2

Preparation for testing

R
Before every CRI Piezo test routine, check the oil
level gage to ensure there is sufficient test oil in the
tank.
R
We recommend performing a leak test on a daily ba-
sis (sealing plug with connection adapter). The leak
test can be called up under "Service >> Equipment
diagnosis".
R
To prevent contamination of the test oil, every CRI
Piezo component must be cleaned before the test.
Do not clamp damaged, contaminated and/or se-
verely corroded CRI Piezo for testing.
Robert Bosch GmbH
Operation | 1 687 010 400 | 15
4.3

Cleaning instructions for CRI Piezo

!
Do not clean the nozzle cone with a brass brush,
steel brush or the like as this would damage the in-
jection orifices. Do not clean injection orifices with
the nozzle cleaning tool 0 986 611 140. Do not clean
the electrical connection of the injector with cold
cleaning agent.
1. Seal the inlet connection, return connection and noz-
zle cone of the injector/nozzle holder with protective
caps or cover over.
2. Use a plastic brush to remove any coarse dirt on the
injector/nozzle holder.
3. Pre-clean the injector/nozzle holder with cold clean-
ing agent.
!
Use the cleaning agent Tickopur TR 13 or a compara-
ble corrosion and coke-dissolving cleaning agent for
ultrasonic cleaning.
4. Remove the protective cap from the nozzle cone.
5. Attach the injector/nozzle holder to a suitable hold-
ing device and immerse it in the ultrasonic bath until
the nozzle retaining nut is completely covered by the
cleaning agent.
6. Set a cleaning temperature of 60 °C to 70 °C.
7. After approx. 15 minutes, take the injector/nozzle
holder out of the ultrasonic bath and blow dry with
compressed air.
i
After cleaning, always store injectors/nozzle holders
in a clean, closed container to prevent the injectors/
nozzle holders coming into contact with dirt parti-
cles (e.g. fluff, swarf).
i
Also heed the additional cleaning information in the
ESI[tronic] 2.0 component repair instructions.
en
|
1 689 989 197
2014-04-01