Type 460-93 transmitter:
1. Check that the transmitter's system switch (A) is in position 1 (OFF).
2.Check that the code switch (B) 9 is in the + (plus) position.
3.Set codes on the transmitter's 3 first switches (code switches 1-3)
which are identical to the receiver's (code switches 4-8 are not used).
4. Check that the relay is actuated when one of the transmitter's buttons
is pressed in.
See code table 460-93,Appendix C.
NOTE!
When you select the door on the T60TX-15DML transmitter, a combi-
nation of the first digit and the last two digits is entered when it works
together with a 460-93 transmitter.
Example:. If you want to operate door A2 as set out in table A, then enter
the combination 102, to operate door D3 as set out in table D, enter the
combination 403, etc.
T60TX-0XSHL/-SOL/-STL AND T60TX-15SML
Type 401L-406L transmitter:
1.Check that the transmitter's system switch (A) is in position 1 (OFF).
2. Set codes on the transmitter's code switch (B) 1-8 identical to the
existing receiver (9-10 not used).
3. Check that the relay is actuated when the same function button is
pressed again.
1
(A)
1 2 3
ON
+
0
1
2
2
3
1
3
4
5
6
(B)
4
5 6 7 8 9 1 0
173