Type 460-93 transmitter:
1. Check that the transmitter's system switch (A) is in position 1 (OFF).
2. Check that code switch (B) 9 is in the + (plus) position.
3. Set codes on the transmitter's 3 first switches (code switches 1-3)
identical to the receiver's codes (code switches 4-8 not used).
4. Check that the relay switches when one of the transmitter buttons is
pressed.
See code table 460-93,Appendix C.
Note:
When you select the port on the T60TX-15DML transmitter, a combina-
tion of the first digit and the last two digits is entered when used together
with a 460-93 transmitter.
Example: In order to control port A2 in accordance with table A, enter
the combination 102; to control port D3 in accordance with table D, enter
the combination 403; and so on.
T60TX-0XSHL/-SOL/-STL AND T60TX-15SML
Type 401L-406L transmitter:
1.Check that the transmitter's system switch (A) is in position 1 (OFF).
2. Set codes on the transmitter's code switches (B) 1-8 identical to the
existing receiver (9-10 not used).
3. Check that the relay switches when the same function button is
pressed again.
1
(A)
1 2 3
ON
+
0
1
194
2
3
1
2
3
4
5
6
(B)
4
5 6 7 8 9 1 0