MAINTENANCE

Troubleshooting

System Diagnostic Fault History
The drive continuously monitors system performance and can detect a variety of abnormal conditions. In
many cases, the drive will compensate as needed to maintain continuous system operation; however, if
there is a high risk of equipment damage, the drive will stop the system and display the fault condition.
If possible, the drive will try to restart itself when the fault condition subsides. Each time a fault is de-
tected in the system, the drive records the fault with the date and time the fault was detected. A maxi-
mum of 100 events are recorded. Events can be viewed and retrieved with the USB device or the mobile
app.

Diagnostic Fault Codes

Codes
Fault
F F 1 1
Motor
Underload
F F 2 2
Undervoltage
F F 3 3
Overcurrent or
Locked Pump
F F 4 4
Incorrectly
Wired
F F 5 5
Output Open
Phase
Possible Causes
Over-pumped well
Broken shaft or coupling
Blocked screen, worn pump
Air/gas locked pump
SubDrive not set properly for
pump end
Underload Sensitivity setting
incorrect
Drive is in thermal foldback
Low line voltage
Miswired input leads
Loose connection at breaker or
panel
Motor and/or pump
misalignment
Dragging motor and/or pump
Motor and/or pump locked
Abrasives in pump
Excess motor cable length
Input and output wires are
swapped
Loose connection
Defective motor or drop cable
Wrong motor
Corrective Action
Frequency near maximum with load less than configured
underload sensitivity (SubDrive Connect Plus mobile app)
System is drawing down to pump inlet (out of water)
High static, light loading pump - reset Underload Sensitivity
setting (in the programming menu and mobile app) if not out
of water
Check pump rotation, reconnect if necessary for proper
rotation
Air/gas locked pump - if possible, set deeper in well to
reduce
Verify MAX AMPS setting (in the programming menu and
mobile app) is correct. For FE MagForce application, make
sure MAX AMPS matches pump load's rated current.
If the drive is in thermal foldback, see corrective actions for
fault code F7.
Line voltage low, less than approximately:
- 155 VAC (normal 230 operating range = 190 to 260)
- 290 VAC (normal 460 operating range = 380 to 520)
Check incoming power connections and correct or tighten if
necessary
Incorrect incoming voltage — check fuses, contact power
company
Amperage is above MAX AMPS at minimum frequency
Remove and repair or replace as required
Reduce motor cable length. Adhere to Maximum Motor Cable
Length table.
For FE MagForce application, verify motor model selection,
pump load, and max amps.
Check wiring, check motor size, adjust or repair as needed
Open reading on DC test at start.
Check drop cable and motor resistance, tighten output con-
nections, repair or replace as necessary.
Use dry motor to check drive functions. If drive runs and ex-
hibits an underload fault, drive is good.