Patient Monitor
The Patient Monitor application emulates a typical hospital patient monitor . It is the
learner' s console and can be set up and controlled by the instructor, as well as by
the learner, through on- screen touch menus .
Session Viewer and SimView Server
Session Viewer and SimView Server are applications that record video and patient
monitor screen captures during simulation, in addition to providing an interface
to debrief your session . After a session is ended, log files generated in LLEAP are
transferred and merged with the video files in Session Viewer or SimView Server
for the debrief .
Session Viewer typically runs locally on the same computer used for LLEAP,
SimView Server runs on a dedicated server in the local network . During the first
start-up of LLEAP you are prompted to select a debriefing system available on
your computer or local network . This can be changed later .
Other Applications
There are also other programs that are used in conjunction with the simulation
sessions, for example License Manager for handling program licenses and Simulator
Firmware & Network Fixer for updating the firmware of the simulators or
troubleshooting network problems .
SimDesigner
SimDesigner is an application for configuring your own pre-programmed scenarios .
It can also be used to analyze and print out a graphical representation of a scenario .
SimDesigner must be installed to allow conversion of legacy instructor application
files to LLEAP compatible file formats .
For a full overview of all applications and their help files, start LLEAP Home .
Web Downloads
Visit www.laerdal.com/downloads to download the latest User Guide and
Software .
Unpack
The ALS Simulator is packaged without the legs attached . Remove the upper body
and legs from the packaging and attach the legs to the torso .
Attaching the Legs:
To attach the Right Leg (with enclosed air tank):
1 . Remove bladder reservoir from pelvis .
2 . Remove blank genitalia module from pelvis .
3 . Carefully slide the tubing and wiring exiting the fixed bolt from the upper thigh
of the right leg through the connector hole and into internal cavity of pelvic
area . (Photo 1)
Photo 1
4 . Continue to advance the bolt and wiring though the connector hole until the
thigh is flush with the pelvis of the simulator .
5 . From inside pelvic area, thread the longer air connection tube first through the
provided washer, spring, and thumb nut in that order . Then, thread the shorter
electronic wire through the washer, spring, and thumb nut .
6 . Connect the wire and cable inside the pelvis .
7 . Tighten the thumb nut until desired articulation is achieved .
8 . Replace bladder reservoir in torso .
9 . Replace blank genitalia module in pelvic region of torso .
To attach the Left Leg:
1 .
Remove left thigh injection pad (A), genitalia module (B) and bladder
reservoir assembly (C)
A
Photo 4
2 .
Select and prepare hardware (Photo 2), pass spring and small washer over
bolt (Photo 3)
3 .
To install pass bolt assembly through thigh, then pelvis opening from outside
inward (Photo 4), select large fender washer and pass over bolt from inside
simulator abdominal cavity . Screw wing nut onto bolt (Photo 5)
4 .
Replace bladder reservoir and genitalia module in pelvis and injection pad in
thigh . (See Step 1)
NOTE: Tighten wing nut as desired to simulate leg range of motion .
3
B
C
Photo 2
Photo 3
Photo 5