Disassembly And Disposal - SICK SureSense HTB18 Manual De Operación

Ocultar thumbs Ver también para SureSense HTB18:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 36
8

DISASSEMBLY AND DISPOSAL

8
Disassembly and disposal
9
Maintenance
6
LED indicator/fault pattern /
LED indicator/fault pattern
Yellow LED lights up, no object
in the path of the beam /
Yellow LED lights up, no object
in the path of the beam
Object is in the path of the be‐
am, yellow LED does not light
up /
Object is in the path of the be‐
am, yellow LED does not light
up
The sensor must be disposed of according to the applicable country-specific regulati‐
ons. Efforts should be made during the disposal process to recycle the constituent ma‐
terials (particularly precious metals).
SICK sensors are maintenance-free.
We recommend doing the following regularly:
Clean the external lens surfaces
Check the screw connections and plug-in connections
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
Cause /
Cause
/ Distance between the sen‐
sor and the background is too
short /
/ Distance between the sen‐
sor and the background is too
short
Distance between the sensor
and the object is too long or
sensing range is set too
short /
Distance between the sensor
and the object is too long or
sensing range is set too short
Measures /
Measures
power supply, check all electri‐
cal connections (cables and
plug connections).
Reduce the sensing range,
see graphic F /
Reduce the sensing range,
see graphic F
Increase the sensing range,
see graphic F /
Increase the sensing range,
see graphic F
8017850 | SICK
Subject to change without notice

Publicidad

Tabla de contenido
loading

Tabla de contenido