ENGLISH
THOR 103
COD. 6909500060
6. REINSTALL THE ELECTRODE BY PUSHING IT
STRIGHT INTO THE TORCH HEAD UNTIL IT CLICKS.
7. Reinstall the desired starter cartrige and tip into the torch head
8. Hand tighten the shield cup until it is seated of the the torch head.If resistance is felt
when installing the cup, check the threads before proceeding.
12.5 GUIDE FR THE FAULTS RESOLUTIONS
This subsection covers troubleshooting that requires dissassembly and electronic
measurements.It is helpful for solving many of the common problems that can arise
with this torch assembly.
How to use this guide
The following information is a guide to help the customer / operator determine the most
likely causes for various symptoms.
This guide is set up as follows:
X. symptom (bold type)
Any special instruction (text type)
Cause (italic type))
a.
Check/remedy (text type)
Locate your symptom, check the causes (easiest listed first) then remedies.repair as
needed being sure to verify that unit is fully operational after any repairs.
Troubleshoting
A. torch will not pilot when toc switch is activeted
1.
red led always on.
a.
Check that shield cup is properly installed.
2.
upper O-ring on torch head is in wrong position.
a.
Remove shield cup from torch;check position of upper O-
ring.Correct if necessary.
STEL s.r.l. – Via del Progresso n° 59 – 36020
Loc. Castegnero (VICENZA) - ITALY
TEL. +39 444 639525 (central.) – +39 444 639682 (comm.)
FAX +39 444 639641 – E-mail: stel @ stelgroup.it
http: www.stelgroup.it
TECHNICAL
DESCRIPTION
135
ENGLISH
THOR 103
COD. 6909500060
6. REINSTALL THE ELECTRODE BY PUSHING IT
STRIGHT INTO THE TORCH HEAD UNTIL IT CLICKS.
7. Reinstall the desired starter cartrige and tip into the torch head
8. Hand tighten the shield cup until it is seated of the the torch head.If resistance is felt
when installing the cup, check the threads before proceeding.
12.5 GUIDE FR THE FAULTS RESOLUTIONS
This subsection covers troubleshooting that requires dissassembly and electronic
measurements.It is helpful for solving many of the common problems that can arise
with this torch assembly.
How to use this guide
The following information is a guide to help the customer / operator determine the most
likely causes for various symptoms.
This guide is set up as follows:
X. symptom (bold type)
Any special instruction (text type)
Cause (italic type))
a.
Check/remedy (text type)
Locate your symptom, check the causes (easiest listed first) then remedies.repair as
needed being sure to verify that unit is fully operational after any repairs.
Troubleshoting
A. torch will not pilot when toc switch is activeted
1.
red led always on.
a.
Check that shield cup is properly installed.
2.
upper O-ring on torch head is in wrong position.
a.
Remove shield cup from torch;check position of upper O-
ring.Correct if necessary.
STEL s.r.l. – Via del Progresso n° 59 – 36020
Loc. Castegnero (VICENZA) - ITALY
TEL. +39 444 639525 (central.) – +39 444 639682 (comm.)
FAX +39 444 639641 – E-mail: stel @ stelgroup.it
http: www.stelgroup.it
TECHNICAL
DESCRIPTION
135