The general options available are as follows:
Fast Start and Backoff -
VTBI -
Set VTBI over Time -
Induction -
Multidose -
Rate Lock -
Quiet Mode -
Pressure Alarm -
Max. Pressure Alarm -
Auto Pressure Alarm -
AC Fail Alarm -
Rate Titration -
NEOI Warning -
EOI Point -
KVO at EOI -
Beam Alarm -
Weight -
Purge Rate -
Bolus -
Default Bolus -
Cap Bolus Rate -
Cap Rate -
Display Event Log -
Log Last Patient Only -
Nurse Call -
Nurse Call Inverted -
Comms Pump Address -
Comms Monitor Only -
Comms Odd Parity -
Comms ASCII -
7001FAOPT73 ISS 13
Enables drive slack fast start and occlusion auto bolus reduction.
Enables or disables the VTBI function.
Sets a specific volume to be infused over a fixed period of time.
Enables or disables the induction option.
Enables or disables the multidose option.
If enabled, the rate can be locked to prevent tampering of the set
infusion rate.
If enabled, the low priority alarms and button pushes are muted.
Sets the pressure alarm value. Default is 300mmHg.
Sets the maximum pressure limit. Default is 750mmHg.
Enables or disables the automatic pressure alarm option.
Enables or disables the AC Fail Alarm.
If enabled, the rate can be changed whilst the pump is infusing.
To titrate a rate while infusing, use the rate adjust keys to select
the new rate and press the START button to confirm the new rate.
Sets the NEOI warning from 1 to 15mins.
Sets the end of infusion volume as a percentage of the syringe
volume from 0.5% to 5.0%.
If enabled the pump will switch to run at the KVO rate - 1.0ml/h
(or the current set rate if this is lower) at the EOI point. If disabled
the pump will stop at the EOI point.
Sets up the default beam level between 0 and 7.
Sets up the patient weight between 0.1kg and 150kg. Default is
70.0kg.
Sets the purge rate between 100 and 500ml/h. The upper limit
prevents excessive loss of fluid whilst purging.
Enables bolus delivery.
Sets the default bolus rate between 10 and1200ml/h.
Sets maximum permissible value for the bolus rate.
Sets maximum permissible value for the infusion rate.
If enabled the event log can be accessed via the options menu.
If enabled the event log shows only the last patient (since new
patient selected). If disabled the complete log can be viewed.
Enables or disables the nurse call feature.
When enabled the nurse call feature is inverted.
Sets the Pump Communications Address.
When disabled, allows remote control of the unit from the comms
link. Monitor is always possible.
If enabled, communications parity is odd.
If enabled, communications protocol is in ASCII.
Configured Options
General Options
23 / 87