Specifications
Pressures
Maximum Static Pressure
Supply Pressure Differential*
Minimum Flow Rate (less than 72 psi dynamic pressure,
500 kPa maintaining pressure)
Minimum Flow Rate (greater than 72 psi dynamic
pressure, 500 kPa maintaining pressure)
Maximum Flow Rate
Temperatures
Programmable Temperature
Default Temperature at Start-up
Minimum Mixed Temperature Differential from Hot
Supply
Temperature Stability at Recommended Supply Conditions +/- 1.6°F (1°C)
Ambient Temperature
Maximum Relative Humidity
Electrical
Electrical Rating
Digital Interface Cable Length (supplied)
*In commercial applications where there is a large difference in hot and cold supply pressures or frequent fluctuation in
either supply line is anticipated, it is strongly recommended that pressure regulators be installed.
This valve complies with ASME A112.18.1/CSA B125.1, ASSE 1016/ASME A112.18.1016/CSA B125.16, UL1951, CSA C22.2
No.14, CSA C22.2 No.68, and NOM 003. This valve is listed with ASSE, IAPMO/cUPC, and UL.
The digital valve is equipped with BLUETOOTH
®
The BLUETOOTH
word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such
marks by Kohler Co. is under license. Other trademarks and trade names are those of their respective owners.
Kohler Co.
125 psi, 862 kPa, 8.6 bar
Max 5 psi, 34.5 kPa, 0.34 bar (equal pressures
recommended)
1.6 gal/min (6 l/min)
2.1 gal/min (8 l/min)
8 gal/min (30.3 l/min) per outlet, 13 gal/min (49.2 l/min)
total at 45 psi, 310.3 kPa, 3.1 bar
Max 120°F (49°C), Min 86°F (30°C) Full cold may also be
selected.
100°F (38°C)
3.6°F (2°C)
Greater than 34°F (1°C), Max 104°F (40°C)
95% non-condensing
120 V, 0.16 A, 60 Hz
20' (6.1 m)
®
technology allowing communication through the KOHLER Mode App.