How to select a cycle
Push the
to move among the cycles CY1
cycle
.
The 5 programs have the default values shown in the diagrams next page.
1.
CY1: Fast chilling and conservation. (Hard + soft chilling and holding)
CY2: Chilling and fast freezing. (Hard + soft chilling, freezing and holding)
2.
CY3: Fast freezing. (Fast freezing and holding)
3.
4.
CY4: Fast freezing with alarm and stop. (Only fast freezing)
5.
H: Hold mode function. (Hard chill or freezing)
6.
dEF: For starting a manual defrost.
How to display the holding SET point.
While the Holding cycle is running (H-icon
lighted), push the
The Holding set point is displayed on the
upper display and the SETH labels is
displayed on the bottom display.
How to modify the holding SET point.
While the SETH is displayed, hold the
key pressed until the SETH label starts
flashing.
Use the arrow keys to modify the value and
press the
key to confirm.
To confirm and exit, push the
How to start a cycle.
Push the
key and the selected cycle starts.
The yellow display is switched on.
Compressor is delayed by 3 min.
How to pause a cycle.
Push the
key and the compressor and fan
will stop.
Stb will flash in the display during the pause.
Push the
key to restart the cycle from the
point of interruption.
In any case the cycle automatically restarts
after the PAU time. (See manual)
How to stop a cycle.
Hold the
key pressed untill the yellow
display switch off and the cycle is stopped.
10
key.
key again.
, CY2
, CY3
, CY4
and the holding