ELECTRICAL CONNECTIONS

Complete the installation in line with low voltage regulations and applicable rules.
Use cables with sufficient section, and always earthed.
Check the manufacturer's instructions for all the elements installed.
Power supply and operator connections
Connect a direct current ERREKA operator
(24Vdc). Connecting a different direct current
motor to ERREKA motors may produce
incorrect operation, and may lead to accidents
and failures due to the force limiter of the
control panel not working properly.
IZAR Operator
O
IZAR operator: ensure that the limit switches
are correctly connected. If they are not, the
motor will continue to operate until wheel A
or B reaches the stopper, thus breaking the
mechanism.
O
This type of motor does not need condensers
for operation.
VCD
Vcd motor-reducer connection
VCD
Vcd motor-reducer connection
FCMA A operation limit switch connection
COM
Limit switches common connection
FCMB B operation limit switch connection
FCA
Opening limit switch connection
FCC
Closing limit switch connection
The connection of the limit switches depends on
each particular installation: in some installations
FCMA will coincide with FCA and FCMB with
FCC, whilst in others it will be the other way
round. The verification is done by testing.
INSTALLATION
VIVO-D103 / ADB30 Control Panel
45