DESCRIPTION OF THE PRODUCT
Dead Man mode (DIP1 OFF and DIP2 OFF)
In this case the gate cannot be operated using the
remote control.
4

BEHAVIOUR IN THE FACE OF AN OBSTACLE

The gate can detect an obstacle in two ways:
A- Detection by additional safety device (photocell or strip)
Automatic or semi-automatic mode
A During opening
The gate continues to open even when the safety
device detects an obstacle.
B During closing
If the safety device detects an obstacle during the
closing operation, the gate stops and opens completely.
B- Direct detection (sensitivity of the operator)
The panel reacts before obstacles both in opening and
closing. There is an adjustable torque limiter, which
halts the operation of the motor when the torque
(impact force) exceeds the selected value. During
closing it also inverts the movement direction.
5

DECLARATION OF CONFORMITY

Erreka Automatismos declares that the VIVO-D103 /
ADB30 control board has been designed for use in a
machine or for assembly along with other elements in
order to form a machine in line with Directive 2006/42/EC.
The VIVO-D103 / ADB30 control boards allow
installations which fulfil Standards EN 13241-1 and EN
12453, provided they are installed appropriately and
correctly. The installer shall be responsible for proper
installation.
42
Installation Manual
Opening (HPC chip):
opening is started by briefly
pressing the A.T. button, finishing when the limit switch
is reached. There is soft stop at the end of the
operation.
Opening (HPAC chip):
the A.T. button pressed down (the gate halts if
released). This finishes when reaching the limit switch.
The opening operation is carried out at maximum speed
(no slow start-up or soft stop).
Standby:
the gate remains open indefinitely until a
button is pushed.
Close:
it is necessary to keep the close button pressed
down (C.T.). The closing operation is carried out at
maximum speed (no slow start-up or soft stop).
When reaching the limit switch, the gate halts even
when the button is still being pressed.
Dead Man mode
A During opening
The gate continues to open even when the safety
device detects an obstacle.
B During closing
If the safety device detects an obstacle during the
closing operation, the gate stops. When the obstacle
disappears, the gate continues to close.
NOTE: with the panel in Dead Man mode, there
is no sensitivity in the face of obstacles.
VIVO-D103 / ADB30 control boards comply with safety
legislation, in line with the following directives and
standards:
• 2006/95/CE (low voltage materials)
• 2004/108/EC (electromagnetic compatibility)
• EN 60555-2
opening is done by keeping

Publicidad

loading

Este manual también es adecuado para:

Adb30