MAINTENANCE AND DIAGNOSIS OF FAILURES
Problem
The gate opens but does not close
DL3 remains on
The gate opens but does not close
DL3 remains off
The gate opens but does not close
DL4 remains off
3

SPARE PARTS

If the panel needs repairing, go to an
authorised assistance centre or manufacturer;
never try to repair it yourself.
4

SCRAP

The control panel, up until the end of its useful
life, must be dismounted at its location by an
installer who is as well qualified as the person
who completed the assembly, observing the
same precautions and safety measures. In this
manner we will avoid possible accidents and
damage to adjacent facilities.
54
Installation Manual
Cause
The panel is programmed in step-
by-step mode
Opening limit switch activated,
poorly connected or deteriorated
Closing limit switch activated,
poorly connected or deteriorated
Use only original spare parts.
}
The control panel must be deposited in the
appropriate containers for subsequent recycling,
separating and classifying the different materials in
line with their nature. NEVER deposit it in domestic
rubbish or in landfills which are not suitably
controlled, as this will cause environmental
contamination.
Solution
Programme it in automatic mode,
where appropriate
Check the limit switch
Check the limit switch