1 – snooze/light button
2 – number of temperature/humidity and
wind sensor 1/2/3
3 – outdoor temperature
4 – cycling through data from connected
sensors
5 – outdoor temperature trend
6 – outdoor humidity trend
7 – weather forecast
8 – moon phase
9 – pressure history
10 – pressure value
11 – pressure trend
12 – indoor temperature alert
13 – indoor temperature
14 – indoor temperature trend
15 – station batteries low
16 – indoor humidity trend
17 – indoor humidity
18 – alarm no. 1/no. 2
19 – time, DCF signal reception, daylight
savings time (DST)
20 – day of the week
21 – UP button – step forward in settings,
memory of max/min temperature and
humidity
22 – date
23 – DOWN button – step back in settings
24 – wind direction indicator
25 – CHANNEL button – searching for sensor
signal/switching through information
from connected sensors
26 – wind direction: S – south, W – west,
N – north, E – east
27 – ALARM button – alarm activation/deac-
tivation

Technical specifications:

clock controlled by DCF77 radio signal
time format: 12/24 h
indoor temperature: -10 °C to +50 °C, 0.1 °C resolution
outdoor temperature: -30 °C to +60 °C, 0.1 °C resolution
temperature measurement accuracy: ±1 °C for 20 °C to +24 °C range, ±2 °C for 0 °C to +20 °C and
24 °C to +40 °C range, ±3 °C for -20 °C to 0 °C and 40 °C to +50 °C range, ±4 °C for other ranges.
indoor and outdoor humidity: 1–99 % RH, 1 % resolution
humidity measurement accuracy: 5 %
displayed units of temperature: °C/°F
barometric pressure measurement range: 800 hPa to 1 100 hPa
unit of pressure: hPa/inHg
wind sensor measurement range: 0 to 127.5 km/h
unit of wind speed: km/mph
28 – SET button – °C/°F unit of temperature
setting, function settings
29 – MODE button – display mode switching
30 – data from precipitation sensor
31 – signal from precipitation sensor
32 – low batteries in precipitation sensor
33 – wind speed
34 – signal from temperature/humidity and
wind sensor
35 – low batteries in temperature/humidity
and wind sensor
36 – outdoor humidity
37 – outdoor temperature alert
38 – low batteries in temperature/humidity
and wind sensor
39 – power adapter socket
40 – battery compartment
41 – stand
42 – alarm speaker
43 – holes for hanging on a wall
44 – precipitation sensor battery cover
45 – precipitation sensor grille
46 – wind sensor cups
47 – compass
48 – south indicator (S)
49 – temperature/humidity/wind sensor
battery compartment
Buttons: TX – send signal from sensor to sta-
tion, 1/2/3 – switch sensor channel number,
WAVE – manually activate/deactivate DCF
signal reception
50 – mounting rod (26 mm diameter)
51 – mounting base
52 – wind direction paddle
4