Manual Mode; Menu "Display" - Hansgrohe Pontos AquaCycle 900 Instrucciones De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Abbreviations
P1 = Submersible pump stage 1
P1 = Submersible pump stage 2
S1 = Sediment pump stage 1
S1 = Sediment pump stage 2
L1 = Air pump stage 1
L1 = Air pump stage 2
LUV = UV lamp
PDR = Pressure pump
PDU = Pump shower
VFi = Valve filter backflushing
MFI = Motor filter backflushing
VTW = Valve drinking water

Manual mode:

In the menu Manual mode you can test all con-
nected consumers directly for their readiness
for operation. All consumers can be active si-
multaneously. (However, this should be avoi-
ded during normal operation!)
In manual mode, the green LED is blinking.
Use the keys
consumer to be tested.
Confirm with button
To deactivate, press button
Menu "Operating values"
In the menu "Operating values", it is possible to
read off operating values such as times and
quantities. This also includes the UV lamp's
operating hours.

Menu "Display":

In the menu Display it is possible to set the
background lighting and the display contrast.
Use the buttons
desired item.
Confirm with button
ges to the setting.
050608
or
to select the
.
again.
or
to select the
. The display chan-
Operating instructions AquaCycle 900
Use
or
to change the value.
Confirm with button
saved.
Menu "Messages"
The message Messages displays facility mal-
functions that do not lead to abortion of the
automatic program. If any messages are on
hand, the red LED "Malfunctions" glows.
Reading messages:
Use the keys
or
sages in the main menu.
Confirm with button
Use button
to confirm the message.
Please contact the after-sales service if a
malfunction occurs repeatedly.
Menu "Configuration"
In the menu Configuration you can select
whether the facility is to operate with one or two
air pumps.
Changing mode:
Call menu Configuration.
Use the buttons
Operation air pump 1
Confirm with button
Use
to increase value "1" to "2". The
display changes from Operation air pump 1
to Operation air pump 2. Both air pumps
are now activated.
. The new setting is
to select Mes-
.
or
to select
.
EN17

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido