B: Lacking service water supply
Possible cause
no power supply
Shut-off valve in the service
water line is closed
(Position: above the filter back-
flush valve)
no water in stage 3
Pressure pump does not deliver
any water
C: Smell / bad service water quality
possible cause
faulty installation
Facility malfunction
EN34
Operating instructions AquaCycle 900
Inspection

Visual inspection:

1. Room and facility protection
2. Fuse on facility circuit board
Function test of drinking
water backfeed in manual
mode
Checking the sensor elec-
tronics (see chapter "Facility
operation")
Checking the control panel dis-
play at the pressure pump (see
chapter "Pressure pump")
Inspection
Check:
"What kind of water gets
into the facility?"
Separate venting of the
intake? (e.g. roof vent)
Drain trap to the sewage
system at the facility outlet?
Room ventilation available?
Checking the air pumps (see
chapter "Facility components")
Checking the sediment pumps
(see chapter "Facility operation")
Remedial measures
Determine the reason for the
shutdown!
if necessary re-engage the fuse
or
replace the circuit board fuse
Open the shut-off valve
Actuate the drinking water back-
feed several times during man-
ual mode
Determine the cause of the
water shortage or overheating!
Vent pump
If necessary, replacement of the
pressure pump by Pontos or a
qualified electrician
Remedial measure
only feeding of:
shower and bath water
wastewater from hand wash
basins
Operation only with separate
venting, drain trap and room
ventilation
Cleaning, if necessary replace-
ment of the defective compo-
nent by Pontos or a qualified
electrician
050608