Submersible pump
The submersible pumps pump the treated wa-
ter from stage 1 to 2 or from stage 2 to 3.
Checking the submersible pump:
If the submersible pumps are switched on, wa-
ter must flow into stage 2 or 3.
Cleaning / replacing the submersible pump:
1. Unplug the facility's mains plug.
2. Unplug the submersible pump's connecting
plug at the rear of the shelf.
3. Pull the submersible pump unit from the
tank: The pipe is flexible and may be bent.
4. Remove hose on submersible pump.
5. Pass the submersible pump's connecting
plug together with the cap through the tank
to the inside.
6. Clean / replace pump unit.
7. Mount the new submersible pump in re-
verse order.
8. Check function according to chapter Menu
tree.
Submersible pump
050608
Operating instructions AquaCycle 900
Submersible pump connecting plug
EN27