Malfunction
The waste water drain hose is clogged 1. Open the dosing unit cover at the drain hose.
Malfunction
INSERT KIK
WRONG KIK
NO PERMISSION
RELEASE HANDLE SWITCH!
BATTERY LOW
BATTERY EMPTY
WATER FLOW ERROR
DRIVE MOTOR OVERLOAD
DRIVE MOTOR BLOCKED
(1)
(2)
(3)
(4)
red
-
-
-
red
-
-
-
red
-
-
green
red
-
-
green
red
-
green
-
red
-
green
green
red
-
green
green
red
green
-
-
red
green
-
green
red
green
-
green
red
green
green
-
red
green
green
green
A: Packaging unit, B: Quantity required by the device
Description
Roller brush, red (medium, standard)
Roller brush, white (soft)
Roller brush, orange (high / low)
Roller brush, green (hard)
Roller brush, black (very hard)
Microfiber roller
Pad roller shaft
Roller pad, yellow (soft)
Roller pad, red (medium)
Roller pad, green (hard)
Rectification
2. Pull the suction hose off the suction bar and close it by hand.
3. Set the program switch to a programme with suction.
The blockage is sucked out of the drain hose into the waste water tank.
Malfunctions with information shown on the display
Cause
No intelligent key inserted.
The inserted Intelligent Key does not authorise the execution
of the selected function.
The inserted Intelligent Key does not authorise the execution
of the selected function.
When the device is switched on, a driving lever is operated.  Release both driving levers.
The battery is almost empty. The cleaning functions of the de-
vice are automatically switched off.
The battery is empty. The cleaning functions and the travel
drive are switched off.
The electric water valve is defective.
The current consumption of the driving motor is too high.
The driving motor is blocked.
Li-Ion battery status indicator
Status LED
1
Indicator LED 1
2
Indicator LED 2
3
Indicator LED 3
4
Indicator LED 4
5
Battery
6
Button
7
1. Press the button for 5 seconds.
● No LED lights up: Charge the battery.
(5)
Cause
-
The battery is too hot.
green
The battery management system is too hot.
-
The battery is too cold for charging.
green
The current consumption during charging is
too high.
The current consumption of the device is too
high.
green
Short-circuit.
-
Cell voltage too low during discharge.
green
Cell voltage too high during charging.
green
The battery voltage is too low.
-
Malfunction during charging process.
green
-
The battery is too cold to output power.
-
Power output malfunction.
Cleaning head with roller brushes accessories
Part no.
4.035-184.0
4.762-409.0
4.762-410.0
4.762-411.0
4.762-412.0
4.114-010.0
4.762-415.0
6.369-732.0
6.369-734.0
6.369-733.0
Rectification
 Insert an intelligent key.
 Use a different Intelligent Key.
 Possibly have the Intelligent Key used activated (depending on
the case).
 Use a different Intelligent Key.
 Possibly have the Intelligent Key used activated (depending on
the case).
 Drive the device to the charging station and charge the battery.
 Switch off the device, wait briefly and switch it on again. The drive
to the charging station. If necessary, push it to the charging station
when it is switched off. Charge the battery.
 Contact customer service.
 Check the travel drive train for foreign objects.
 Find a path with a lower gradient.
 Switch off the device, wait briefly, switch the device on again.
 Check the travel drive train for foreign objects.
 Jack up each drive wheel individually and check whether it can be
turned.
Rectification
Allow the battery to cool down.
Allow the battery to cool down.
Move the device to a warmer place and wait until the battery has warmed up.
Unplug the mains plug of the charger. Wait 10 seconds. Reinsert the mains
plug. If the malfunction is displayed again, replace the charger.
Switch off the device. If the malfunction occurs again after switching on, look
for the fault in the device.
Check all battery connections.
Charge the battery.
Discharge the battery to 20% remaining capacity. Then charge the battery.
Charge the battery.
Unplug the mains plug of the charger. Wait 10 seconds. Reinsert the mains
plug. If the malfunction is displayed again, replace the charger.
Move the device to a warmer place and wait until the battery has warmed up.
Switch off the device. If the malfunction persists, contact Customer Service.
Accessories
Description
Red standard roller brush for maintenance cleaning.
White roller brush for cleaning sensitive floor coverings.
Orange roller brush with high-low structure for particularly effective cleaning of struc-
tured floor coverings.
Green abrasive roller brush for basic cleaning and for removing strongly adhering dirt. 1
Black, particularly abrasive roller brush for basic cleaning of insensitive floor cover-
ings with particularly adherent dirt.
Ideal for fine stone tiles. Microfibre roller for reliable and gentle removal of grey film. 1
Pad roller shaft made of aluminium to accommodate roller pads or microfibre rollers. 1
Yellow roller pad for cleaning and polishing non-textured floor coverings.
Red standard roller pad for maintenance cleaning of non-textured floor coverings.
Green abrasive roller pad for basic cleaning as well as for removing strongly adhering
soiling on non-structured floor coverings.
English
● The status LED lights up green: Together, all 5
LEDs indicate the battery charge state.
● The status LED lights up red: The indicator LEDs
indicate a malfunction. Malfunctions described in
the following table can be remedied by the user.
Contact KÄRCHER Customer Service in the case of
fault displays that are not described above.
A
B
1
2
1
2
1
2
2
1
2
2
2
20
40
20
40
20
40
21

Publicidad

loading

Este manual también es adecuado para:

1.533