4.2 SUGGESTIONS IN CASE OF INCONVENIENCES
CLOGGING OF THE PIPES
THE AMOUNT OF SEED IN KG/HA DOES NOT CORRESPOND TO
THE VALUES OF THE ROTATION TEST
The causes involved in the excessive amount of seeds
dispersed may be:
The causes involved in an insuffi cient amount of seed
dispersed may be:
5.0 DEMOLITION AND DISPOSAL
This operation is to be carried out by the customer.
Before demolishing the machine, you are advised to carefully check its physical condition and ascertain whether there are any parts of
the structure that may be susceptible to structural collapse or breakage during demolition.
The customer should operate in compliance with the environment protection laws in force in his/her country.
The machine demolition operations should be carried out by skilled personnel only, equipped with suitable protective clothing
(safety footwear and gloves) and auxiliary tools and equipment.
All the disassembly operations for demolition should be carried out with the machine stopped and detached from the trac-
tor.
Before demolishing the machine, you are advised to render harmless all the parts that may be a source of danger and therefore:
- scrap the structure using specialized fi rms,
- remove any electrical apparatus according to the laws in force,
- collect oils and greases separately, to be disposed of through specialized fi rms, in accordance with the regulations of the country in
which the machine was used.
When the machine is demolished the CE mark should be destroyed together with this manual.
Last but not least, we remind you that the Manufacturer is always available for any and all necessary assistance and spa-
res.
cod. G19503231
USE AND MAINTENANCE
CAUSES
- Check, on the basis of the rotation test chart, the position of
the butterfl y valves (Fig. 60, page 72).
- The blades are clogged with wet soil
- The distribution pipes are bent somewhere.
- Foreign bodies in the distributor or blade.
- Respect the rpm, 540 or 1000, of the power take-off.
- The blower pump rpm has been reduced because of worn
V-belts.
- the sealing rims are defective and no longer adhere, because
of wear or mice eating them away.
- during the rotation test the drive transmission wheel was turned
too fast.
- dosing unit access clogged by foreign bodies.
- during the rotation test the empty weight of the collecting
container was not taken into account and deducted.
The differences due to slipping or excessive distribution at the
beginning of the fi eld, are around 2-4%. Greater deviations
can be traced back exclusively to errors in the rotation test,
to a wrong transmission ratio or similar causes.
CAUTION
ENGLISH
REMEDYS
EN - 83