Press "Previous"
to return to the settings screen (start
screen). The heater is now ready for the next heating.
The heating process can be stopped at any time by pressing the
"Stop" button
.
Time mode:
Determine whether all the settings are as desired (section 7).
Alter the desired time, if necessary.
Activate the "Log" function, if desired.
NOTE!
The desired time and desired power do not have to be set if an
inductor with identification feature is connected. In this case
the generator automatically adopts the settings defined in the
program (1, 2 or 3) for the corresponding inductor.
Press "Start"
. The process starts and the following screen
appears.
Press "info"
for further information on the heating process
and the following screen is displayed.
Schaeffler Technologies
Press "Previous"
to return to the previous screen.
The process runs according to the set value, irrespective of which
of the two screens is displayed.
When the set value is reached, the process stops and the most
recent data from the process are displayed.
Press "Previous"
to return to the settings screen (start
screen). The heater is now ready for the next heating.
The heating process can be stopped at any time by pressing the
"Stop" button
.
Temperature or time mode:
Determine whether all the settings are as desired (section 7).
Alter the desired temperature and time, if necessary.
Activate the "Hold temp" and "Log" functions, if desired.
NOTE!
The desired temperature, desired time and desired power do
not have to be set if an inductor with identification feature
is connected. In this case the generator automatically
adopts the settings defined in the program (1, 2 or 3) for the
corresponding inductor.
Press "Start"
. The process starts and the following screen
appears.