SANITATION
PROBE
INSERTION
SANITATION
DURATION
CONDENSER
OVERHEATING
COMPRESSOR
LOCKED
NEEDLE PROBE
INSERTION
Sanitation alarm.
To correct:
-
check that the needle probe has been correctly inserted and check the value of
parameters r17 and r18.
Main results:
-
the sanitation cycle will be interrupted.
Alarm indicating that sanitation has not been completed within the maximum duration of the
first phase.
To correct:
-
check the value of parameter r23
Main results:
-
the device will save the alarm
-
the cycle underway will be interrupted
-
the alarm output will be activated
Condenser overheat alarm.
To correct:
-
check the condenser temperature
-
check the value of parameter C6.
Main results:
-
the condenser fan will be switched on
-
the alarm output will be activated
Compressor locked alarm.
To correct:
-
check the condenser temperature
-
check the value of parameter C7
-
disconnect the device from the power supply and clean the condenser.
Main results:
-
if the error occurs during "stand-by", it will not be possible to select or start up an
operating cycle
-
if the error occurs during an operating cycle, the cycle will be interrupted.
-
the alarm output will be activated
Needle probe not inserted alarm.
To correct:
-
check that the needle probes have been correctly inserted and check the value of
parameters r17 and r18.
Main results:
-
the temperature controlled cycle in progress will be converted to a time controlled
cycle.