by using an hard bristle brush or any other
appropriate tool, carefully clean the body and
the recessed and/or hidden areas.
•By unscrewing the aprropriate screws (12)
remove the frame (8) with the grid and his
basket and leave them fully immersed in the
basket with the solution prepared above for
the time required, then, by using an hard
bristle brush or any other appropriate tool,
carefully clean the body and the recessed
and/or hidden areas.
•By unscrewing the appropriate screws (13),
remove the the extrusion flange (24) and pull
out the small grid (25). Separate the gasket
(16) and the second sealing gasket from the
flange (24). Leave them fully immersed in the
basket with the solution prepared above for
the time required, then, by using an hard
bristle brush or any other appropriate tool,
carefully clean the flange and his recessed
and/or hidden areas. Pay attention in
particular to the gaskets sites and to the rails
where the gate (9) gets stuck.
•With an hard bristle brush wet with the water
+ detergent solution or any other appropriate
tool, caefully clean the surrounding machine
area where the flange hooks up. Pay attention
to the zone around the extrusion opening and
to the threads under the pot.
•Final rinsing all the removable parts with
water at tap temperature for at least 5 minutes
fully immersed.
•Rinse carefully the cleaning tool in the
clensing operations.
•Repeat the process at least one time or until
the machine will be perfectly cleaned.
Remount all the gasket and reposition the
pieces on the machine, then proceed with the
disinfection operations. ATTENTION: when
mounting the pieces, the screws must be
tightened by hands.
D I S I N F E C T I O N
decontamination involves the verified
destruction of non spore forming pathogenic
bacteria and significant reduction of non
pathogenic and non spore forming bacteria.
Cleansing and disinfecting operations must be
performed separately. After cleansing,
proceed with disinfection. Proceed as follows:
•Use a specific disinfecting agent suitable for
food industry sector. For the best result in the
disinfection operations we suggest to use the
10
. D i s i n f e c t i o n o r
English
Purdy Products company Stera-Sheen™
Green Label (2oz per 2gal (7.5g per liter)
water diluted solution for at least 5 minutes
surface contact time). Carefully read the
instructions provided by manufacturer of the
sanitizing agent.
•Dilute the disinfecting product following the
instructions given by the manufacturer.
Attention: using less disinfecting product
than recommended may promote bacteria
proliferation at dangerous levels, as well as
using excess active principle does not
improve efficiency.
•Leave the disinfecting agent to act for the
time required, in any case no less than 5
minutes. If left less time than required,
disinfection may be ineffective.
•Leave the cloth you'll use to disinfect the
machine and any other appropriate tool you'll
use in the disinfection procedures fully
immersed in a separate basket filled with
sanitizing solution for the time required (no
less than 5 minutes). Before using, apply (or
spray) the disinfecting agent directly on the
tools. Repeat the sanitization procedure of
the tools anytime you complete any
disinfection operation. Assemble all sanitized
componnets into the machine wearing
sanitary gloves.
•Place 1-gallon of cool rinse water into the
bowl. Brush clean bowl.
•Plug the machine to the mains, turn on the
main power switch (10), turn on the paddle by
rotating the knob (2) clockwise, set the half
speed paddle and agitate for 2 minutes.
Drain rinse water. Switch to "off" position.
Repeat rinsing procedure until water is clear.
•Dissolve 1-Oz. (half packet) Stera-Sheen
Green label, in 1-gallon of warm water. Pour
the solution into the bowl. Brush clean bowl
and outlet hole and gate (25).
•Turn on the paddle by rotating the knob (2)
clockwise to agitate for at least 5-minutes.
Drain all solution by pulling the gate (9).
Switch to "Off" position. Switch off the
machine by rotating the power switch (10)
and unplug from the mains.
•Leave out the paddle (5) and the ring (4) from
the pot and the lid (3) from the machine.
•By using the wet cloth previously immersed in
the sanitizing solution, carefully apply the
disinfecting agent on the bowl (pay utmost

Publicidad