Fault
Load cannot be lifted
or is not lifted on first
pump stroke.
Load cannot be
lowered.
Z
If the fault cannot be rectified after carrying out the remedial procedure, notify the
manufacturer's service department, as any further troubleshooting can only be
performed by specially trained and qualified service personnel.
C 6
Possible cause
– Hydraulic oil level too low.
– Air in hydraulic system.
– Handle (2) pressed in
"neutral" position or in "S"
direction.
– Seals leaking, valves do not
close.
– Lift cylinder damaged.
Action
– Check hydraulic oil level.
– Pump load handler fully
upwards to bleed the
hydraulic system.
– Press handle (2) in "H"
position.
– Inform manufacturer's
service department.
– Inform manufacturer's
service department.