6.3 Motor Brush Replacement
To prevent motor damage, the ZU4 motor brushes incorporate
an automatic motor stop when one of the brush carbons wears
to a length of 0.25" [6 mm]. Inspect both brushes.
1.
Disconnect pump from electrical power.
DANGER: To avoid possible electrocution, pump must
be completely disconnected from electrical power
before brush servicing is attempted.
2.
Remove both brush caps (A) by defl ecting the brush cap
latch (B) and gently prying outward (see Figure 10).
3.
Remove motor brushes by turning black cap counter-
clockwise.
4.
Replace
both
brushes
reassemble.
B
Figure 10, Brush Cap Removal
A. Brush Cap
and
reverse
procedure
A
B. Brush Cap Latch
7.0 TROUBLESHOOTING
(See Troubleshooting Guide)
Only qualifi ed hydraulic technicians should service the pump or
system components. A system failure may or may not be the
result of a pump malfunction. To determine the cause of the
problem, the complete system must be included in any diagnostic
procedure.
The following information is intended to be used only as an aid in
determining if a problem exists. For repair service, contact your
local Authorized Enerpac Service Center.