6 Other
6.1 Switching on
After switching on the machine, the letters
"StA" (StArt) appear in the display for a few
seconds which indicates the initialization of
the machine. Then "LDP" appears, which
means loading parameter list. Then the
machine is ready foroperation.
If "FLr" (Flash error) is displayed, an internal
memory error of the machine occured.
If the machine was turned off during a lapse
of time and the P32 parameter was set to
"on", the last saved full minute running time
is restarted.
6
.4 Readout serial number
For service purposes or software updates, it
is important to know the serial number of the
device. The serial number is either visible on
a sticker which is attached on the electronics
or it can be readout by the software: Press
7 Electronic coin
Validator (only EMS-82)
The electronic coin validator is programmed
to specified coins in different tolerances.
Each of these coins can be locked separate-
ly by setting a lock switch.
Lock switch to ON (up) disables
the corresponding channel.
lock switch to OFF (down) activates
the corresponding channel.
Normal Validation
Coins are analyzed in normal tolerance ranges. This is the default factory setting.
Strict Validation
Coins are analyzed in strict tolerance ranges. Improved detection of counterfeits. The acceptance of the set
coin type has been slightly decreasing. The lock switch "normal" must be set to ON.
Very strict
Coins are analyzed in very strict tolerance ranges. Improved detection of counterfeit coins. The acceptance of
Validation
the coin type continues to decline. The lock switch "normal" and "strict" must be set to ON.
Blocking switch
If the coin should not be accepted at all, all validation channels for this coin must be blocked.
DE/FR/IT/EN/ES/NL/CS/LT/PL/HU/RU/BG
6.2 Factory default settings
To reset the machine with factory default
settings, turn it off at first. Then keep the
buttons "+" and "-" pressed simultaneously
while switching on the machine. "dFL"
(default = basic settings) appears in the
display.
6.3 Software version
With parameter P99 details about the soft-
ware version can be read out. Press + / - to
switch between the subparameters P99-1
to P99-6.
and hold the "P" key during power up of the
machine, then the 8-digit serial number will
appear in couples (from left to right). The first
digit of the couple indicates the position and
the last the individual value.
Figure 9: Electronic coin validator / lock switches
= Cointype
= Normal-Validation
WM 22 ml
WM 26 ml
= Strict-Validation
0,10 EUR
= Very strict-Validation
0,20 EUR
0,50 EUR
= Blocking switch
1,00 EUR
2,00 EUR
WM 28 ml
36
P99-1
Software version
P99-2
Language / coin tgable
1 = German
2 = Englisch
3 = German-Switzerland
4 = Denmark
5 = Latvia
6 = Norway
7 = Czechia
P99-3
Feature 1
P99-4
Feature 2
P99-5
Feature 3
P99-6
Feature 4
Example:
Nr.: 00001564 The display shows in
sequences:
"1-0" -> "2-0" -> "3-0" -> "4-0" ->
"5-1" -> "6-5" -> "7-6" -> "8-4" -> Start
Lock switches 1 – 16
on
1
13
1 2 3 4 5 6 7 8
2
13
1 2 3 4 5 6 7 8
4
14
14
5
12
12
6
11
11
7
9
9
15
10
10
13
3
DIP
on
DIP
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16
IMPORTANT:
Lock switch has to be OFF