The set-up menu
Accessing the setup-menu
"MIG/MAG standard / pulsed-arc welding", "TIG welding",
"Manual electrode welding" and "2nd" process
N.B.! The mode of functioning is explained here with the
reference to the "MIG/MAG standard welding" process. The
procedure for changing other parameters is identical.
- Plug in the mains plug
- Shift the mains switch
- Use the Process button
process.
- Use the MIG/MAG mode button
standard program-mode".
- Press down and hold the MEM button
- Press the Process button
- Release the MEM button
The power source is now in the set-up menu for the function
"MIG/MAG standard welding", and the first parameter GPr (Gas
pre-flow time) is displayed.
"Special 2-step mode for automatic interface", "Aluminium
4-step" mode and "Spot welding"
N.B.! The mode of functioning is explained here with the
reference to the "Aluminium 4-step" process. The procedure for
changing other parameters is identical.
- Plug in the mains plug
- Shift the mains switch
- Use the Process button
process.
- Use the Torch mode button
step" process.
- Press and hold the MEM button
- Press the Torch mode button
- Release the MEM button
The power source is now in the set-up menu of the Torch mode
"Aluminium 4-step", and the first parameter I-S (Starting cur-
rent) is displayed.
Changing the parameter
- Use the Process button
- Use the adjusting dial
Exit the set-up menu
- Press the MEM button
N.B.! Any alterations you have made will be activated when you
change a parameter and/or exit the set-up menu.
into the "I" position
to select the "MIG/MAG welding"
to select the "MIG/MAG
into the "I" position
to select the "MIG/MAG welding"
to select the "Aluminium 4-
to select the desired parameter
to alter the value of the parameter
Parameters for "MIG/MAG standard / pulsed-
arc welding" process
GPr... Gas pre-flow time ... 0 - 9.9 s, Factory setting: 0,1 s.
GPo... Gas post-flow time ... 0 - 9.9 s, Factory setting: 0,5 s.
Fdc... Soft-start ... AUT / OFF / 0,5 - maximum w i r e s p e e d
(e.g. 22.0 m/min), Factory setting: AUT
N.B! If Fdc is set to AUT (automatic), the value from the welding
program databank is used. If Fdc values are set manually and
these values are faster than the wirefeed speed that was set for
the welding operation:
- the speed at which the wire is actually fed during feeder-
creep will be the same as the wirefeed speed that was set for
the welding operation
Fdi ... Inching speed ... 0 - maximum wirespeed (e.g. 22.0 m/
min), Factory setting: 10 m/min
bbc ... Burn-back ... +/- 0.20 s, Factory setting: 0
FAC... Factory ... Reset the welding machine to factory settings
Press and hold the MEM button
the machine to its original (i.e. factory) settings. If the
display reads "PrG", then the welding machine has been
reset.
Warning! When you re-set the welding machine, all the
personal settings you may have made in the Set-up
menu: Level 1 will be lost.
N.B!
When you reset the welding machine, jobs are not
deleted, but continue to be stored in the memory. The functions
in the second level of the set-up menu (2nd) are not deleted
either. Exception: The "Ignition time-out" parameter (ito).
2nd ... Second level of the set-up menu (see the section headed
"The setup menu: Level 2")
Parameters for "TIG welding"
2nd ... Second level of the set-up menu (see the section headed
"The setup menu: Level 2")
Parameters for "Manual electrode welding"
process
N.B! When you re-set the welding machine,
- for the MIG/MAG standard / pulsed-arc welding process,
- with the parameter Factory (FAC),
- the parameters Hot-current time (Hti) and Hot-start current
(HCU) will also be reset.
Hti ... Hot-current time ... 0 - 2.0 s, Factory setting: 0.5 s
HCU... Hot-start current ... 0 - 100 %, Factory setting: 50 %
2nd ... Second level of the set-up menu (see the section headed
"The setup menu: Level 2")
50