Checklist For The Manufacturer/Oem - SICK L 4000 Manual De Instrucciones

Ocultar thumbs Ver también para L 4000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 118
Chapter 11
The details on the items listed below must be available at the latest when the system is commissioned for the first
time, depending, however, on the various applications the requirements of which must be reviewed by the manufac-
turer/OEM.
This checklist should be retained and kept with the machine documentation to serve as reference during recurring
tests.
1. Did the safety regulations in accordance with the regulations/standards applicable to the ma-
chine serve as a basis for its design?
2. Are the applied directives and standards listed in the declaration of conformity?
3. Does the protective device comply with the required control category?
4. Is the access to the hazardous area/hazardous point only possible through the protective field
of the ESPE?
5. Have appropriate measures been taken to prevent (mechanical point-of-operation guarding) or
monitor unprotected presence in the hazardous area when protecting a hazardous area/hazar-
dous point and have these been secured against removal?
6. Are additional mechanical protective measures fitted and secured against manipulation which
prevent reaching below, above or behind the ESPE?
7. Has the maximum stopping and/or run-down time of the machine been measured, specified
and documented (at the machine and/or in the machine documentation)?
8. Has the ESPE been mounted such that the required safety distance from the nearest hazardous
point has been achieved?
9. Are the ESPE devices properly mounted and secured against manipulation after adjustment?
10. Are the required protective measures against electric shock in effect (protection class)?
11. Is the control switch for resetting the protective devices (ESPE) or restarting the machine pres-
ent and correctly installed?
12. Are the outputs of the ESPE (OSSDs) integrated in compliance with the required control cate-
gory and does the integration comply with the circuit diagrams?
13. Has the protective function been checked in compliance with the test notes of this documenta-
tion?
14. Are the given protective functions effective at every setting of the operating mode selector
switch?
15. Are the switching elements activated by the ESPE, e.g. contactors, valves, monitored?
16. Is the ESPE effective over the entire period of the dangerous state?
17. Once initiated, will a dangerous state be stopped when switching the ESPE on or off and when
changing the operating mode, or when switching to another protective device?
18. Has the information label "Important Information" for the daily check been attached so that it is
well visible for the operator?
This checklist does not replace the initial commissioning, nor regular inspections by specialist personnel.
328
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Appendix A

11.2 Checklist for the manufacturer/OEM

Checklist for the manufacturer/OEM for installing
electro-sensitive protective equipment (ESPE).
Operating Instructions
L 4000 system
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
8010009/TI69/2009-11-26

Publicidad

Tabla de contenido
loading

Tabla de contenido