FAULTS
CONVERTING THE POWER SUPPLY (0S0FR3E - 0S1FR4E)
NOTE: The appliance is supplied at an
operating voltage of 400V/3N (indicated on
the sticker applied to the nameplate); the
conversion to 230V3~ can be carried out as
described below.
HAZARD: Before doing any work, turn
off the general power supply.
Pull off the knobs (A).
1)
A
Remove the test voltage sticker from the
6)
nameplate and apply the new one to high-
light the voltage being used.
NOTE: After completing the opera-
tion, check for any faults.
3413910_inst_GB_rev.1
E
B
B
C
Undo the screws (B) to remove the control
2)
panel (C).
Modify the connections to the heating ele-
3)
ment terminals (D) as shown in the wiring dia-
gram at the end of the manual.
Fit the jumper (E) to make the electrical con-
4)
nection of L3 with N.
After completing the operation, fi t everything
5)
back in place.
ENGLISH
D
400V3N
D
230V3