Descargar Imprimir esta página

Corghi EM9780 plus Manual De Uso página 75

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

-
press the
button on the monitor to
confirm and switch to the width value entry
phase;
-
Change the displayed value to the value
measured using the manual calliper (Fig. 21).
-
press the
button on the monitor to
confirm and switch to the diameter value
entry phase;
-
Change the value of the diameter displayed
by entering the value indicated on the tyre
using the keypad.
-
Press the Exit
the manual data setting.
Note: When dimensions are set manually, clip
EM9780 plus - EM9780 C plus AutomaticLine - Operator's manual
20
21
button to terminate
or adhesive weights must be applied manually
in the 12 o'clock position.
3. Suite WHEEL DIAGNOSIS PROGRAMME
(available only if rear ultrasonic sensor is
present)
3.1. Radial and lateral runout measurement
This function is used to determine the causes of
disturbance (vibration) generated by geometric
deformation of the rim and/or tyre, which may
still persist even after a thorough balancing
procedure.The machine indicates that the pro-
cedure needs to be performed by displaying the
following war-ning light
can decide to perform the procedure whenever
considered necessary.
To do this, perform a spin.
To do this, pull the sensor manually with the
knob on the back of the wheel (see Fig.11c) and
then launch.
If a wheel assembly is mounted, the following
icons are displayed on the screen at the end of
the spin indicating:
-
the radial run-out of the wheel (1st harmonic);
-
the radial run-out of the wheel peak-to-peak;
-
the lateral run-out of the wheel (1st harmonic);
-
the lateral run-out of the wheel peak-to-peak;
. The operator
UK
75

Publicidad

loading

Este manual también es adecuado para:

Em9780 c plus automaticline