7.3.1 Calling up the user web interface
Requirement:
ü During commissioning, the qualified electrician
has connected the product to the same network
your terminal device is connected to (e. g.
smartphone, tablet, laptop).
u Open web browser on terminal device (e. g.
smartphone, tablet, laptop).
The user web interface can be reached via
http://IP address.
Example:
n IP address: 192.168.0.70
n The user web interface can be reached via:
http://192.168.0.70
Due to dynamic assignment, the IP address is not
known
If the IP address is not known due to dynamic as-
signment via DHCP, the web interface can be
reached via the type / serial number. It is indicated
on the name plate of your product as follows: Type
number.Serial number
1 "3.2 Rating plate" [} 7]
u Open the web browser and enter the
type / serial number according to the following
pattern: http://ANtype numberSNserial number
Example:
n Type / serial number (on the name plate):
1384202.10364
n Required entry in web browser: http://
AN1384202SN10364
Special feature: Depending on the router and firm-
ware version used, an add-on may be required to
allow the web interface to be accessed by means
of the above procedure, e.g. if a Fritzbox is used,
the add-on .fritz.box may be required. (http://AN-
type numberSNserial number.fritz.box).
Username and password
u Enter the username (user) and password.
1 Password: See Setup data sheet
The login information for the "operator"
might also be listed on the setup data
sheet. Entering this information opens the
web interface for commissioning, which
may only be performed by a qualified elec-
trician.
u Open the web interface only by entering
the "user" login information.
Since the user web interface has been
available only as of firmware version 5.22,
the password for products delivered with an
earlier firmware version is not included in
the setup data sheet. In this case, the pass-
word is: green_zone
It is in your own interest to change the
password after the first login.
It is not possible to call up the user web interface
If it is not possible to call up the user web interface,
check the following requirements:
n The product is switched on.
n The product and the terminal device (e. g.
smartphone, tablet, laptop) are integrated in the
same network.
If a connection to the user web interface still cannot
be established, the configuration could be faulty,
for example. Please contact your responsible ser-
vice partner.