Reset button
The reset button is designed to:
- reset any Mifare keys configured and, subsequently,
proceed with a new configuration.
- set the relay activation time in the event it is activated by
the exit button or by the Mifare key.
Note that the setting of the relay activation time must also be
repeated in the apartment stations.
Relay activation time configuration
Should the relay be activated from an indoor station, the
activation time can be set from the indoor station itself.
Should the relay be activated by a Mifare key or exit button,
then the activation time also needs to be set on the outdoor
station too.
The following procedure describes the configuration of the
relay activation time via the outdoor station:
1) With the front not installed, press the reset button on the
outdoor station for 10s: the device will respond with a
sequence of 2 (two) beeps and the call button LEDs will
flash.
2) In this status, press the call button in the top left corner,
to set the relay activation time if activated via Mifare key
or exit button.
If no buttons are pressed, the time will be set to 1s by
default
Depending on the number of times the button in the top
left corner is pressed, the time indicated by the following
sequence will be set, in seconds: 0.5,1,2,3,4,5,6,7,8,9,10.
3) The procedure ends after 4s of inactivity
4) 2 (two) beeps and the LEDs that stop flashing indicate
the end of the procedure.
Configuring the administration keys
1) With the front not installed, quickly press the reset button
on the outdoor station twice: the device will respond with a
sequence of 4 beeps. The configuration procedure begins
from this moment and is signalled by the slow flashing of the
call buttons; any previous configurations are deleted.
2) Bring the first key up to the RFID reader; the device will emit
a long beep; the first key is configured as "administration
key for addition".
We recommend marking the key with "key for addition"
3) Bring the second key up to the RFID reader; the device
will emit a long beep; the second key is configured as
"administration key for removal".
We recommend marking the key with "key for removal".
The administration keys and all user keys can be reset by
repeating the above procedure from the beginning.
4) If no other action is carried out, the registration procedure
will end after 5 seconds with a warning tone (4 beeps).
Any new configuration of the administrator keys and user
keys will be possible, repeating the above procedure from the
beginning.
The front case can now be installed on the outdoor station,
taking care to close the anti-tamper key.
36
Adding a user key
For the addition and removal of user keys, the front of the
outdoor station does not necessarily have to be opened. These
operations can also be carried out after the first-time system
installation.
1) Bring the "administration key for addition" up to the RFID
reader: the device will beep and the call buttons will start to
flash slowly.
2) Bring an unprogrammed key up to the reader. The device
will enable it as a "user key". The device will beep when the
configuration is complete.
3) Repeat step 2) to add any other keys.
4) The procedure for enabling user keys will end after about 5
s of inactivity.
The device will beep 4 times and stop flashing to indicate the
end of the procedure.
The keys added using this procedure will immediately be
available for the activation of locks, as specified below.
Removing user keys
A user key can only be removed using the actual key itself, as
specified below.
1) Bring the "administration key for removal" up to the RFID
reader; the device will beep.
2) Bring a user key up to the reader. The device will disable it.
The device will beep when the configuration is complete.
3) Repeat step 2) to remove any other keys.
4) The procedure for disabling user keys will end after about 5
s of inactivity.
The device will beep 4 times to indicate the end of the
procedure.
Key reading
To read a key, simply place it on the outdoor station reader,
which can be identified by the symbol [
If the key is recognised, the outdoor station will beep once; if
the key is not recognised, the outdoor station will beep twice.
If the key is kept in place for a short time of up to 2 s, the
electrical lock will be activated.
If the key is kept in place for longer than 3 s, another beep will
sound and the relay will be activated.
].