Power supply: Universal 85-265 VAC, 50-60Hz
Average consumption: 12W; ~ 52mA
Relay outputs: N° 2 dry contact - 8A, 250Vac resistive load (R1; R2)
N° 2 Proportional Outputs:
- N° 1 mA Output : maximum load of 600ohm
- N° 1 pulse emitter relay : dry contact relay (R3) ( similar to a water meter pulse emitter)
Other inputs: Flow sensor, Pause input (dry contact)
Options
- 3rd measure input (to be selected among Rx, Chlorine, CD)
- 2nd proportional output: mA
- Alarm buzzer
- Data communication: 1 ETHERNET port
CONTENTS OF DELIVERY
N°1 V-MS instrument with power cord
N°1 Manual of use and maintenance
V-MS DESCRIPTION
V-MS measures and regulates physical / chemical parameters. Refer to the label affixed to the instrument for your model.
V-MS offers basic functions for applications related to water treatment and has the features described in the following
paragraph.
Rev 6.0
Maximum output voltage 15V.
Galvanically isolated from all other inputs and outputs.
Maximum switching frequency : 2 Hz
Galvanically isolated from all other inputs and outputs.
Weight = 1200gr
I = 27cm
L = 27cm
H = 11cm
Cod. 00.008.764
DIMENSIONS
PACKING