MAINTENANCE (continued)
Spa Tub Drainage
1.
Turn off and unplug the spa control unit.
2.
Connect the drain valve adaptor to a garden hose and point the
other end of the garden hose to a suitable draining area
(see drawing 13).
3.
Remove the drain valve cap from outside of the spa tub and attach
the drain valve adaptor to the drain valve (see drawing 13).
4.
From inside of the spa tub, open the drain valve cap, water will start
flowing out from the garden hose.
5.
When the water stops draining, disconnect the spa control unit from
the spa tub wall. Lift the spa tub wall from the side opposite the drain,
leading any remaining water to the drain and emptying the spa
completely (see drawing 14).
6.
Turn over the spa tub to empty any remaining water (see drawing 15).
7.
Use a clean towel to wipe up any remaining water and moisture on the
spa tub and spa control unit.
8.
Ensure the spa tub and spa control unit are thoroughly dried.
NOTE: The enclosed plugs (15 & 23) can be used to cover the water
inlet and outlet connectors from the inside of the spa tub to prevent
water from flowing out.
Spa Tub Cleaning
If dirt is visible in the water or water becomes cloudy and proper water
chemistry does not clear it up, change the water and clean the spa tub.
See "Spa Tub Drainage" section on how to drain the spa.
While empty, remove the cartridge housing from inside of the spa tub wall, clean and/or replace the filter
cartridge. Use a sponge and mild soap solution to wipe away any soil or stains on the inside of the spa wall.
Rinse thoroughly before refilling with clean water.
IMPORTANT: Do not use steel wool, hard brushes or abrasive cleaners.
Biofilm Removal
See your local spa professional for biofilm removal products and advice.
Spa Tub Air Valve Fastening
Check the spa tub air valve for leakage and tightness before use. If air is
leaking from the air valve, use the provided wrench (22) to tighten the air
valve as follow:
1.
Make sure the spa tub is deflated, open the air valve cap and insert
the wrench (22) into the air valve body (see drawing 16).
2.
With one hand, hold the backside of the air valve base from the
inside of the spa tub wall and turn the wrench (22) clockwise.
IMPORTANT: Never adjust the air valve base when the spa is in use or filled with water. Only use the
air valve wrench if the air valve is loose or there is leakage around air valve base. Do not over tighten
the air valve: over tightening can damage the valve. Just ensure the air valve is snug and not leaking.
Spa Cover
Inspect the spa cover regularly for leaks, premature wear and tear, damage, or signs of deterioration. Never
use a worn or damaged cover: it will not provide the level of protection required to prevent unsupervised
access to the spa by a child.
Clean the cover inside and outside periodically using a sponge and a suitable solution that includes
adequate disinfection (10 mg per liter of free chlorine). Do not use steel wool, hard brushes or abrasive