ELECTRICAL CONNECTION
Important
The connection must be made by autho-
rised, skilled personnel, in accordance with
the relevant legal requirements, using ap-
propriate and specified materials.
The appliance is supplied with operating voltage
400V/3N, which can be switched to 230V3 (see
page 18).
Caution - warning
Before doing any work, cut off the mains elec-
tricity supply.
Connect the appliance to the mains electricity sup-
ply as follows.
1 - If not already present, install a circuit-breaker
(A) with overload cutout and differential
safety breaker close to the appliance.
2 - Undo the screws (C) and remove the con-
trol panel (B).
3 - Connect the circuit-breaker (A) to the terminal
board (D) of the appliance as shown in the dia-
gram and in the electrical system diagram at
the back of the manual.
IT
CONVERSION OF ELECTRICITY SUPPLY
GB
The appliance is supplied at an operating voltage
400V/3N (indicated on the sticker applied to the
DE
dataplate); conversion to 230V/3 can be carried out
as described below.
FR
Caution - warning
ES
Before doing any work, cut off the mains elec-
tricity supply.
1 - Undo the screws (B) and remove the control
panel (A).
2 - Fit the jumper (C) to make the electrical con-
nection of the terminals (D).
3 - Change the connections of the terminal board
(E) as shown in the diagram.
4 - Replace the control panel.
English
A
Use a cable with at least H05RN-F characteristics.
Important
When connecting, take care to connect the
neutral and earth lines.
4 - Replace the control panel (B) on completion of
the operation.
400V/30N
E
230V/3
E
- 18 -
B
C
D