10 MALFUNCTIONS
Problem
Connect the machine using the cable (fig.2, n°15).
Unlock the emergency stop (fig.1, n°10).
The machine is not running
Close the cover.
Contact your approved agent if the green indicator light is flashing.
Close the front door.
Check whether the blades need replacing (fig.12).
The machine is running, but
Leave the bread to cool down for a few hours.
the loaves are damaged or
cut unevenly
Feed in a loaf of the specified size.
Feed in a loaf that is sufficiently firm.
If the blades are misaligned, adjust the blades and frames.
The bread vibrates between
If the blades are misaligned, adjust the blades and frames.
the blades
Check whether the blades need replacing (fig.12).
The bread is cut too slowly
Choose another pressure setting on your pressure selector (ISC).
Check that the loaf holder springs are in place correctly (fig.14, n°28).
If the blades are misaligned, adjust the blades and frames.
Check that the loaf holder springs are in place correctly (fig.14, n°28).
The bread tears
Check whether the blades need replacing (fig.12).
Contact your approved agent if the green indicator light is flashing.
The bread emerges very
slowly or remains between
Check that the loaf holder springs are in place correctly (fig.14, n°28).
the blades
The bread is squashed
Remove a loaf holder spring and repeat your test (fig.14, n°28).
coming out of the blades
WARNING: The machine must be isolated from the power supply before attempting any work on it.
Should the problem persist, please contact your technician.
Check
15
English
11 ERROR CODES
Flashes or code displayed on
screen
2
Cut-out SECU1 tripped during cycle.
Current to upper actuator (M2) in excess of
3
6 A for 1 second, during advance/cut.
4
Cut motor thermal cut-out (F3) tripped.
No actuator (M2) movement despite tension set
5
to maximum.
Loaf pusher not in initial position. Limit switch S1
6
not tripped.
7
Advance/cut cycle time in excess of 60 seconds.
8
Return cycle time in excess of 30 seconds.
Rear (S1) and front (S2) limit switches tripped at
9
the same time.
Current to upper actuator (M2) in excess of 5 A
10
for 1 second during carriage return.
Front safety cover (S3) open in the course of a
11
cycle.
Should the problem persist, please contact your technician.
English
Problem description
Action
Please restart the
machine using the
emergency stop (fig.1,
n°10). Should the
problem persist, please
contact your technician.
16

Publicidad