Descargar Imprimir esta página

Abicor Binzel iSENSE TRACK ARC 15 Manual De Instrucciones Original página 42

Sensor de guía de costura

Publicidad

Idiomas disponibles

Idiomas disponibles

5 Technical data
Tab. 3
Safety class
Fieldbus interfaces
Power supply for breakout board
Max. cable length
Protection class (recommendation)
Dimensions
Fig. 2
Fig. 3
Isolating Countersink
Inserts (M4
Countersunk Screws)
Ø 4.2 THRO'&C/BORE
Ø 7.2X4.5 DEEP
(M4 Caphead Screws)
EN - 12
Technical data
Device dimensions
75,0
59,1
422
Dimensions of the quick-release plate/cooling element
39.0
40
ARC 15
ARC 30
3R (EN 60825-1:2019)
Ethernet (1000BaseT):
UDP/IP and robot-specific
24 V
(Input range 20 V to 30 V, max. 1.0 A, standard 0.7 A)
50 m from sensor head to breakout board
IP55
40
142.4
9.4
iSENSE TRACK ARC
ARC 50

Publicidad

loading

Este manual también es adecuado para:

Isense track arc 30Isense track arc 50