Descargar Imprimir esta página

LiftMaster MAXUM JDC Serie Manual De Instalación página 28

Operadores industriales de cc ejes de unión, elevador y carro de cc para puertas

Publicidad

Idiomas disponibles

Idiomas disponibles

Wiring Diagram
To prevent possible SERIOUS INJURY or DEATH:
Disconnect electric power and/or battery BEFORE
installing, performing ANY adjustments, or
maintenance. Installation and ALL maintenance
MUST be performed by a trained door systems
To prevent possible SERIOUS INJURY or DEATH:
technician.
Disconnect electric power and/or battery BEFORE installing, performing ANY adjustments, or maintenance.
Installation and ALL maintenance MUST be performed by a trained door systems technician.
BATTERY BOX
+
-
+
-
24Vdc
Battery Accessory SKUs:
DC45AH- 4.5Ah Batteries
DC7AH- 7.0Ah Batteries
TRANSFORMER BOX, 1200
Orange
Orange
Transformer
White
White
1200 Model: Two Rectifiers
TRANSFORMER BOX, 700
Orange
Transformer
Optional Accessories
Brake
(Phase 2)
Hoist Switch
Blue
Purple
Gray
Brown
Rectifier
Rectifier
Rectifier
Orange
700 Model: One Rectifier
Jumpers must be
placed if cables
are not connected
Motor
Gray
Encoder
Module
Gray
Black
 WARNING
For continued protection against fire:
Replace ONLY with fuse of same type and rating.
WARNING
Black Red
Factory
Wired
Field Wiring
Conduit
Conduit
Battery Power Conduit
120V AC or 240V AC EMI FILTER
WARNING
Observe Voltage
Red Red
Black
Black
CLASS 2 SUPPLY +24V
30
30
Replaceable 30A
DC Input from
Automotive Fuses
Transformer/Rectifier
(One pair for 700, two pairs for 1200)
Motor Power
Battery Power Conduit
Factory
Field Wiring
Wired
Conduit
Conduit
28
For continued protection against fire:
Replace ONLY with fuse of same type and rating
Optional Stepdown Transformer
AC Input
Plug transformer connector into
the appropriate voltage that
matches the applied AC voltage
OR
Accessories may connect to the regular or switched port.
Switched is turned off at loss of AC to preserve battery life.
ACCESSORY POWER 24VDC, 1A
DRY CONTACT NOTE:
INTR LOCK jumper MUST
be removed if switch is added.
Ancillary (non-monitored) devices
and dry contact inputs NO/NC.
NOTE: STOP - CMN jumper MUST be
SBC
removed if a 3-Button Station is added.
OPEN
Close - Output 2 (Green)
CLOSE
Open - Output 1 (Green)
STOP
Black
CABLE TENSION
MONITORS
Resistive Edge
XF208VDC and XF600VDC
To use 3-Phase Power, tap any
two phase legs. Use proper
phase balancing.
600VAC to 120VAC
OR
208VAC to 120VAC
480V AC on 480V EMI FILTER
480V comes factory wired
Brown
Blue
50-HERK2
White/Black
Brown
To EYE/EDGE
Blue
White
To CMN
Photo Eyes
CPS-U, CPS-UN4,
CPS-OPEN4, OES-RD16
LC36M
White/Black
White
Tx
Rx
Light Curtain
LC36M

Publicidad

loading