Programming (continued)
WIRING TYPE
DEVICE
Single
Button Wall
Controller
(Wired)
T (continued)
myQ®
Smart
Facility
Access
ACTION
STATE
Operator at OPEN limit
Operator at CLOSE limit
Door opening
Button is
Door closing
pressed
Door at Open Mid-Stop
Door stopped during the open cycle Door closes to the CLOSE limit
Door stopped during the close cycle
Button is held
(constant
Door opening
pressure)
Operator at OPEN limit
Operator at CLOSE limit
Door opening
Open is
pressed
Door closing
Door at Open Mid-Stop
Door stopped during open or close
cycle
Operator at OPEN limit
Operator at CLOSE limit
Door opening
Close is
Door closing
pressed
Door at Open Mid-Stop
Door stopped during open or close
cycle
RESPONSE
Door closes to the CLOSE limit
Door opens to the OPEN limit or Mid-Stop
Door stops
Door will auto reverse to OPEN limit or Mid-Stop
and activates TTC
Door opens to the OPEN limit and activates TTC
Door opens to the OPEN limit or Mid-Stop and
activates TTC
No change in state
No change in state (Recycle timer)
Door opens to the OPEN limit or Mid-Stop and
activates TTC
No change in state
Door will auto reverse to OPEN limit or Mid-Stop
and activates TTC
Door opens to the OPEN limit and activates TTC
Door opens to the OPEN limit or Mid-Stop and
activates TTC
Door closes to the CLOSE limit
No change in state
No change in state
No change in state
Door closes to the CLOSE limit
Door closes to the CLOSE limit