Descargar Imprimir esta página

LiftMaster MAXUM JDC Serie Manual De Instalación página 47

Operadores industriales de cc ejes de unión, elevador y carro de cc para puertas

Publicidad

Idiomas disponibles

Idiomas disponibles

Auxiliary Relays Accessory Kit (AUXREL)
Configure the Relay Adapter
AUXILIARY RELAYS
Aux Relay Switches: Set the AUX RELAY switches as needed to
obtain the desired function as shown below.
J6 Input: Communicator bus connects control board, expansion
board, or relay adapter board.
J7 Input: Communicator bus connects control board, expansion
board, or relay adapter board.
AUX24: Supplies +24Vdc up to 1AMP to wired accessories.
RED/GREEN LIGHT FUNCTIONALITY
Red light wired to AUX RELAY 1. Green light wired to AUX RELAY 2.
DOOR STATE
Closed
Opening
Open
Closing
Defined Mid Stop
Undefined Mid Stop
Timer more than 5
seconds
Timer less than 5
seconds
* For red light ON when door is closed, set switch 1 on AUX RELAY 1 to ON.
Control Board
Entrada de CC del transformador/rectificador
(un par para 700, dos pares para 1200)
CLASS 2 SUPPLY +24V
AUX RELAY 1 SWITCHES
1 OFF
2 OFF
3 OFF
Red light OFF*
Red light ON/Flash
Red light OFF
Red light ON/Flash
N/A
Red light ON
Red light OFF
Red light ON/Flash
(BK)
(WH)
(AUXREL)
RELAY ADAPTER BOARD
(RD)
(WH)
AUX RELAY 2 SWITCHES
1 ON
2 ON
3 ON
Green light OFF
Green light OFF
Green light ON
Green light OFF
N/A
Green light OFF
Green light ON
Green light OFF
RGL24LY (RED / GREEN LIGHT)
(RD)
(BK)
(GN)
(WH)
(GN)
47
RELAY ADAPTER BOARD
N.O.
Com
N.C.
RELAY ADAPTER BOARD
RED
COM
GREEN
N.C.
Com
N.O.

Publicidad

loading