Programming (continued)
MONITORED EYES/EDGE CONFIGURATION
If monitored entrapment protection devices are wired to the system during the initial power-up, they will be learned to
the system, and the operating mode will automatically switch to B2.
If no monitored sensor is attached, the system will default to C2 mode. To manually program an entrapment protection
device, navigate to the SYSTEM SETTINGS > MONITORED EYES/EDGES submenu, otherwise it will Auto-Learn the
monitored device.
MONT EYES/
EDGES
AUTO LEARN ALL
CABLE TENSION MONITOR
To view, or auto learn Cable Tension Monitor navigate to SYSTEM SETTINGS > CABLE TNS MONT
CABLE TNS
MONT
OPERATION MODE (RECOMMENDED)
To change the operating mode from the defaults B2 or C2, navigate to the SYSTEM SETTINGS > OPERATION MODE
submenu.
OPERATION
MODE
BATTERY OPTIONS
To change the operator behavior with battery options, navigate to SYSTEM SETTINGS > BATTERY OPTIONS
BATTERY
OPTIONS
CONNECTIVITY (RECOMMENDED)
To connect the operator to a network, navigate to SYSTEM SETTINGS > CONNECTIVITY > LEARN > LEARN WIFI
submenu. See the "myQ® Smart Facility Access" section to connect your devices to myQ® Business Facility.
CONNECTIVITY
Hold ENTER and DOWN for three seconds to open the System Information Menu.
To learn remotes/transmitters navigate to SYSTEM SETTINGS > CONNECTIVITY > LEARN > SUBMENU. Once in learning
mode, press and release the desired button on the remote/transmitter to learn.
CONNECTIVITY
Remotes
MONT EYES/
MONT EYES/
EDGES
EYE/EDGE 1
CABLE TNS MONT
AUTO LEARN CTM
OPER. MODE
C2:CNST PRES CL
BATTERY OPTIONS
AC FAILURE
LEARN
LEARNING
WIFI
WIFI
LEARN
LEARN
REMOTES
SBC
MONT EYES/
EDGES
EDGES
EYE/EDGE 2
CABLE TNS MONT
LEARN STATUS
OPER. MODE
B2:T/TS/NO TTC
TIMER TO CLOSE
STANDARD
BATTERY OPTIONS
LOW BATTERY
LEARN
REMOTES
REMOTES
OPEN
31
MONT EYES/
EDGES
EYE/EDGE 3
OPER. MODE
D2:CNST PRES
LEARN
LEARN
REMOTES
CLOSE
STOP
MONT EYES/
EDGES
WIRELESS EDGE
OPER. MODE
E2:CNST PRES CL
LEARN
REMOTES
BATCH