2-2.
Accessing Control Panel Menu
6-2.
Acceso al menú del panel de control
4-2.
Accessing Control Panel Menu
2
1
2
OM-270536 Page 22
OM-290047 Página 44
A complete Parts List is available at www.MillerWelds.com
3
3
4
150A
Polarity Selection (Dynasty Only)
Selección del proceso
Select output type AC or DC. With DC selected, the electrode will be negative (DCEN) for TIG, and
positive (DCEP) for Stick.
Process Selection
TIG HF Impulse is a non-contact arc starting method for AC and DC TIG welding (see Section 5-1).
TIG HF Impulse es un método de arranque del arco sin contacto para soldadura TIG en CA y CC (consul-
te la sección 14-1).
TIG Lift-Arc Is a contact arc starting method for AC and DC TIG welding (see Section 5-1).
Stick
Select AC or DC Stick (SMAW) welding.
TIG Lift–Arc es un método de arranque del arco con contacto para soldadura TIG en CA y CC (consulte
la sección 14-1).
Trigger Mode Selection (See Section NO TAG for additional trigger function options).
Soldadura convencional con electrodos: Permite seleccionar la soldadura convencional con electrodos
[RMT] [STD]
(SMAW) en CA o CC.
Typical setting for a remote foot or hand control. RMT STD requires a maintained contact closure to
enable weld output. Amperage can be controlled with a remote potentiometer, or it can be set at the
control panel.
[RMT] 2T [HOLD] (TIG Only)
Remote control required. Allows the operator to weld without holding the trigger closed. To start the
weld, operator presses and releases trigger. To stop the weld, the operator again presses and re-
leases the trigger. In this mode, only the output contactor is controlled by the remote control. Amper-
age must be set on the control panel. (see Section NO TAG).
[OUT] [ON]
Output on. (Stick and TIG Lift Only)
!
Weld output terminals are energized at all times when displays read [OUT] [ON].
No remote control or trigger required. Amperage can be controlled at the control panel or with a remote
potentiometer. Blue output on LED illuminates to indicate output is on.
4
5
1
275861-B
247220-D
1
Memory Button
Select Memory 1-9 (See Section 14)
2
Parameter Display
3
Setting Display
4
Amperage Adjustment Control
Rotate amperage adjustment control
1 Botón Memory (Memoria)
to adjust parameter setting.
5
Amperage Button
Seleccione Memory (Memoria) 1-9 (consulte
la sección 9).
Amperage Control
Controls the welding amperage output.
2 Pantalla de parámetros
Limits the maximum output of a remote
amperage device.
3 Pantalla de ajustes
4 Control de ajuste de amperaje
Gire el control de ajuste de amperaje para
configurar el parámetro.
5 Botón de amperaje
Control del amperaje
Controla la salida de amperaje de la soldadu-
ra. Limita la salida máxima de un dispositivo
de amperaje remoto.
*PRO-SET proporciona ajustes profesional-
mente desarrollados para el proceso de sol-
dadura. Para usar PRO-SET, pulse el botón
menú para visualizar el parámetro y ajuste el
encoder hasta que parpadee PRO-SET en la
pantalla. PRO-SET parpadea una vez y
muestra el ajuste profesional del parámetro.
OM-275857 Page 7