4 - TECHNICAL SPECIFICATIONS
Power supply
Maximum load consumed from
the mains with two motors +
accessories
Nominal load for each motor
output
Max accessories load 24Vdc
Work cycle (*)
Protection fuse
Weight
Dimensions
Working temperature
Protection
Power supply
Maximum load consumed from
the mains with two motors +
accessories
Nominal load for each motor
output
Max accessories load 24Vdc
Work cycle (*)
Protection fuse
Weight
Dimensions
Working temperature
Protection
(*) the work cycle is related to the following conditions:
2 motors @ nominal load
Room temperature = 25°C
CITY2+
CITY2+L
230V / 50Hz 230V / 50Hz
250W
150W
80W
60W
7W
7W
80%
60%
2,5A
2,5A
3000 g
1000 g
295 x 230 x 100 mm
-20 ÷ +60°C
IP55
CITY2+120V
CITY2+BC
120V / 60Hz
ECO-LOGIC
250W
250W
80W
80W
7W
7W
80%
80%
2,5A
-
3000 g
1000 g
295 x 230 x 100 mm
-20 ÷ +60°C
IP55
5 - DESCRIPTION OF THE CONTROL
UNIT
CITY2+ is provided with a display that, not only makes
programming simple, but also allows a continuous monitoring of
the input statuses; in addition, thanks to a menu structure, the
working schedule and the operation logic can be set easily.
In compliance with the European standards concerning electrical
safety and electromagnetic compatibility (EN 60335-1,
EN 50081-1 and EN 50082-1) it has been equipped with the low
voltage circuit total electric insulation (motors included) from the
network voltage.
Other characteristics:
• Power supply protected from short circuits within the controller,
on the motors and on the connected accessories
• Adjustment of the power by partializing the current
• Detecting obstacles by monitoring the current on the motors
(current sensing probe)
• Automatic learning of the operation time.
• Tests for safety devices (photocells, safety ribbons and mosfet)
before each opening.
• Deactivation of safety inputs through the configuration menu:
no jumper is required for terminals concerning safety devices
that have not been installed, yet. You will only need to disable
this function from its relevant menu.
• The device can operate without mains power, by using the
optional battery pack (code 161212).
• Low voltage output that can be used for a signal light or a
24 V flashing light.
• Auxiliary relay with programmable logic for courtesy light,
flashing light or other use.
• ENERGY SAVING FUNCTION