PARAMETER
VALUE
LP.PA
no
Si
Strt
StAn
no
AP.Ch
PrES
oroL
StoP
no
ProS
invE
Fot1
no
AP.Ch
Fot2
CFCh
no
Ch
Ft.tE
no
Si
CoS1
no
AP
APCh
DESCRIPTION
Blinker during pause time
Function deactivated
Blinker will be on during the pause time too
Activation inputs (START and START P.)
This menu allows selecting input operation modes (see chapter 5.3)
Standard mode
Start inputs from terminal board are disabled.
Radio inputs operate in standard mode
Open/Close command
Dead man operation
Timer mode
Stop Input
The input STOP is not available (ignored by the control unit)
The input STOP stops the gate: pressing the command START the gate
continues the motion
The command STOP stops the gate: at the next START the gate starts
moving in the opposite direction
Photocell 1 input
This menu allows enabling the input for type 1 photocells, that is to say,
photocells active both during the opening and closing phase
Input disabled. No jumper with the common is required
Input enabled
Photocell 2 input
This menu allows enabling the input for type 2 photocells, that is to say,
photocells non active during the opening phase
Input enabled even at standstill gate too
Input disabled. No jumper with the common is required
Input enabled for the closing phase only
WARNING: if you select this option, you must disable photocell test
Test of the photocells
In order to achieve a safer operation for the user, the unit performs a
photocells operational test, before a normal working cycle.
If no operational faults are found, the gate starts moving.
Otherwise, it will stand still and the flashing light will stay onfor 5 sec.
The whole test cycle lasts less than one second
Function deactivated
Function activated
Safety ribbon 1 input
This menu allows enabling the input for type 1 safety ribbon, that is to say,
fixed ribbons
Input disabled
Input enabled during the opening and disabled during the closure
Input enabled in opening and closure
StAn
- 41 -
DEFAULT
MEMO
no
StAn
no
no
CFCh
no
no