Descargar Imprimir esta página

V2 12A042 Manual Del Usuario página 39

Cuadro de maniobras digital (24v) para cancelas batientes y puertas correderas

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 70
PARAMETER
VALUE
t.APP
0.0"-1'00
t.Ch1
0.0"-5'00
t.Ch2
0.0"-5'00
t.ChP
0.0" - 2'00
t.C2P
0.5" - 5.0"
no
r.AP
0.0" - 1'00
r.Ch
0.0" - 1'00
t.SEr
0.5"- 1'00
no
SEr.S
Si
no
t.ASE
0.0"- 1'00
DESCRIPTION
Partial opening time (pedestrian access)
When the control unit receives a Start Pedestrian command, it will open
leaf 1 only, for a shorter time. Max allowed time to be setup is
Leaf 1 closing time
Tempo regolabile da 0 secondi a 5 minuti
NOTA: Per evitare che l'anta non si chiuda completamente, è consigliabile
impostare un tempo più lungo di quello di apertura
Tempo di chiusura anta 2
Adjustable time from 0 seconds to 5 minutes.
NOTE: To avoid that the door does not close completely, we recommend
t.AP2
to setup a longer time than
Partial closing time (pedestrian access)
When the control unit receives a Start Pedestrian command, it will use this
time to close the gate. Max allowed time to be setup is
NOTE: To avoid that the door does not close completely, we recommend
t.APP
to setup a longer time than
Leaf 2 closing time during pedestrian cycle
During a partial opening cycle (pedestrian access) leaf 2 may move slightly
because of the wind or its own weight; in this case at closing time leaf 1
could hit leaf 2 and the gate would remain not perfectly closed.
To avoid this, in the last seconds of the cycle a light closing force is applied
to leaf 2 too.
Function deactivated
Opening door delay
During the opening phase, leaf 1 must start moving before leaf 2, to avoid
that both doors may collide.
Leaf 2 opening will be delayed for the setup time
Closing door delay
During the closing phase, leaf 1 must start moving after leaf 2, to avoid
that both doors may collide.
Leaf 1 closing will be delayed for the setup time
Lock time
Before the opening phase begins, the control unit will energize the electric
lock in order to release it and enable the gate motion.
the energizing time.
m
WARNING: in case the gate has no electric lock, set the value
no
Function deactivated
Silent Locking Mode
Function activated
Function deactivated
Lock advance time
While the electric lock is energized, the gate will stay standstill for
time, to make its release easier.
t.ASE
t.SEr
In case
is lower than
the doors will start moving.
m
WARNING: in case the gate has no electric lock, set the value
t.AP1
opening time.
t.Ch1
opening time
t.SEr
, the lock energizing will go on while
- 37 -
DEFAULT
MEMO
6.0"
t.AP1
23.5"
23.5"
7.0"
.
no
1.0"
3.0"
2.0"
time will fix
Si
1.0"
t.ASE
0.0"

Publicidad

loading

Este manual también es adecuado para:

City2+