Descargar Imprimir esta página

Roger Technology ROGER BRUSHLESS B70/1THP Instrucciones Y Advertencias Para El Instalador página 67

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 145
Setting obstacle impact force sensitivity
If the reaction time to obstacle impact force is too long, reduce the value of the parameter. If the impact force exerted
on obstacles is too high, reduce the value of parameter
Low motor torque:
= minimum obstacle impact force ...
N.B.: only use these settings if the medium motor torque values are not suitable for the installation.
Medium motor torque. Recommended setting for adjusting force settings correctly.
= minimum obstacle impact force ...
70% of maximum motor torque, 1 s of reaction time. Sensing edge is compulsory.
80% of maximum motor torque, 2 s of reaction time. Sensing edge is compulsory.
Maximum motor torque, 3 s of reaction time. Sensing edge is compulsory.
Maximum motor torque, 5 s of reaction time. Sensing edge is compulsory.
Setting start acceleration during opening and closing
See chapters 13 and 14
= the gate accelerates rapidly at start of manoeuvre ...
manoeuvre.
Enabling maximum torque boost at start of manoeuvre
If this parameter is enabled, each time the motor starts a manoeuvre, maximum torque is produced for a maximum of
5 seconds, or for the time necessary for the gate to open by approximately 65 cm.
N.B: in the case of HIGH SPEED motors, a motor boost mode is implemented for 2 seconds after each gate start,
regardless of the setting of parameter
Disabled.
Enabled at start of opening manoeuvre only (including position recovery). The motor starting current function is only
enabled for closing manoeuvres if the gate position is known and the gate is over to 2 metres from the completely
closed position.
Enabled for all starts (including position recovery).
Setting motor torque during position recovery
Adjust motor torque with parameter
If position recovery is not completed, normal gate operation will not be resumed.
The response of the obstacle detection system depends solely on the values set for parameters
The response of the obstacle detection system depends on the values set for parameters
current value stored during travel acquisition.
The response of the obstacle detection system is a 70% reduction in maximum torque for a period of 1 s.
The response of the obstacle detection system is a 80% reduction in maximum torque for a period of 2 s.
The response of the obstacle detection system is a 100% reduction in maximum torque for a period of 3 s.
The response of the obstacle detection system is a 100% reduction in maximum torque for a period of 5 s.
Setting opening and closing speed
N.B.:
See chapters 13 and 14
= 6 m/min ...
= maximum speed.
Setting end of manoeuvre constant approach speed
Once deceleration is complete, the gate continues to the limit switch at constant speed. The distance is set with the
parameters
and
.
= 2 m/min;
= 2,5 m/min;
Setting number of automatic closure attempts after activation of sensing edge or obstacle
detection (crush protection)
No automatic closure attempts.
From 1 to 3 automatic closure attempts.
We recommend setting a value equal to or lower than the value set for parameter
Automatic closure is only performed if the gate is completely open.
.
= maximum obstacle impact force
= maximum obstacle impact force.
= the gate accelerates slowly and progressively at start of
.
if, during position recovery, the values set with parameters
= 3 m/min;
= 3,5 m/min;
and
= 4 m/min.
.
and
are
and
.
and on the maximum
67

Publicidad

loading