Parameter description
Value
Function
0
No function (generally off)
1
Generally on
2
Run signal; also by DC-braking
3
Ready signal (no error)
4
Fault relay
5
Fault relay (not at under voltage error)
6
Warning or error message at abnormal stopping
7
Overload alert signal
GB
8
Overtemperature alert signal power modules
9
External overtemperature alert signal motor
10
Only application mode
11
Overtemperature alert signal interior OHI
12...19 Only application mode
20
Actual value = set value (CP.3 = Fcon; rcon; not at noP, LS, error, SSF)
21
Accelerate (CP.3 = FAcc, rAcc, LAS)
22
Decelerate (CP.3 = FdEc, rdEc, LdS)
23
Real direction of rotation = set direction of rotation
24
Utilization > switching level
25
Active current > switching level
26
Only application mode
27
Real value (CP.1) > switching level
28
Setpoint (CP.2) > switching level
29...30 Only application mode
31
Absolute setpoint at AN1 > switching level
32
Absolute setpoint at AN2 > switching level
33
Only application mode
34
Setpoint at AN1 > switching level
35
Setpoint at AN2 > switching level
36...39 Only application mode
40
Hardware current limit activated
41
Modulation on-signal
42...46 Only application mode
47
Ramp output value > switching level
48
Apparent current (CP.4) > switching level
49
Forward running (not at nOP, LS, abnormal stopping or error)
50
Reverse running (not at nOP, LS, abnormal stopping or error)
51
Warning E.OL2
52
Current regulator limit reached
53
Speed regulator limit reached
54...62 Only application mode
63
Absolute value ANOUT1 > switching level
64
Absolute value ANOUT2 > switching level
65
ANOUT1 > switching level
66
ANOUT2 > switching level
67...69 Only application mode
70
Driving current active (safety relay)
71...72 Only application mode
73
Absolut active power > switching level
74
Active power > switching level
75...79 Only application mode
80
Active current > switching level
GB - 20
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
further on next side