Drive mode
3.4
The drive mode
The Drive Mode is an operating mode of KEB COMBIVERT that permits the manual starting of the drive by
the operator. After switching the control release the set value and rotation setting are effected exclusively over
the keyboard. In order to activate the drive mode the corresponding password (see last but one page) must be
entered in CP. 0. The display switches over as follows:
GB
3.4.1 Start / stop drive
3.4.2 Changing the
direction of
rotation
3.4.3 Presetting the
setpoint
3.4.4 Leaving the drive
mode
GB - 24
Direction of rotation
F = clockwise rotation
r = counter clockwise rotation
Modulation
blocked
Drive not controlled
Drive accelerates onto the
adjusted set value
To exit the drive mode the inverter must be in status "stop" (Display noP or LS).
Press the FUNC and ENTER keys simultaneously for about 3 seconds to leave the
drive mode. The CP-parameters appear in the display.
+
Status
noP = no control release
LS = neutral position
Drive decreases to 0
rpm and switches the
modulation off
Drive operates with
adjusted set value
Drive changes
direction of rotation
Display
changes
key is pressed to set value
display/presetting
Set value can be changed
with UP/DOWN at pressed
FUNC/SPEED key
for 3 seconds
when