change. When the appropriate parameter appears on the display, use the "UP" and "DOWN"
buttons to adjust it. Below is a list of parameters that can be changed:
Number
Parameter description
1
Tank pre-cooling temperature
2
Washing time
Hysteresis of the tank pre-cooling
3
temperature
Compressor restart time in
4
standby mode
5
Auto restart time
6
Engine downtime delay
7
Temperature compensation value
8
Alarm about lack of ice mass
NOTE :
It is not recommended to adjust the P1 parameter.
3.4.
Functions description
Cleaning
Activate Cleaning Mode : In standby status, press "CLEAN" button to start Cleaning Mode.
•
The drive motor will be turned on. Press "CLEAN" again to turn off the cleaning mode.
Engine Speed Measurement : Hold the "CLEAN" button for 10 seconds to activate the no-
•
load engine speed measurement function.
Standby mode
Activate standby mode : Press the "STANDBY" button to activate this mode. The compressor
•
will run to freeze the cylinder until it is 70% frozen. The freezing solenoid valve will be turned
off and the pre-cooling solenoid valve will be turned on. When the temperature of the upper
tank reaches the set temperature (P0), both solenoid valves and the compressor will stop.
The compressor will resume operation when the P3 parameter value is reached.
Automatic mode
Activation of automatic mode : Press the "Auto" button to enter automatic mode. The
•
compressor will run to freeze the cylinder 100% and then continue to run to freeze the top
tank until the set temperature (P0) is reached.
Alarm messages
1) No rotation detection : If the limit switch does not detect the mixer rotation (RPM), "--" will
appear on the screen and the machine will beep and stop working.
2) Drive motor speed too slow : If the motor speed is too slow, "NL" will appear on the screen,
the machine will beep and stop working.
3) Limit switch behind the dispenser opening active for more than 1 minute : If the dispenser
is active for more than 1 minute, "Cb" will appear on the screen and the machine will beep
and stop working.
4) Too much mixture in the upper tank : If the mixture in the upper tank is not at the
appropriate level, "QL" will appear on the screen.
EN
Code
The range
of values
P1
2-10
P2
1-30
P3
1-10
P4
5-30
Q5
1-15
P6
1-60
P7
-9~+9
P8
30-50
Default
Unit
value
8
°C
10
minute
2
°C
15
minute
5
minute
thirty
second
0
°C
43
/