ABB EtherCAT FECA-01 Manual Del Usuario página 13

Ocultar thumbs Ver también para EtherCAT FECA-01:
Tabla de contenido

Publicidad

No.
Name/Value
29
DRIVE TYPE CODE
ACS355:
FILE CONFIG ID
ACSM1:
DRIVE TYPE CODE
ACS850/ACS880/AC
S580:
Drive type code
30
MAPPING FILE VER
ACS355:
FILE CONFIG REV
ACSM1:
MAPPING FILE VER
ACS850/ACS880/AC
S580:
Mapping file ver
31
D2FBA COMM STA
ACS355:
FBA STATUS
ACSM1:
D2FBA COMM STA
ACS850/ACS880/AC
S580:
D2FBA comm sta
0 = Idle
1 = Exec.init
2 = Time out
3 = Conf.err
4 = Off-line
5 = On-line
6 = Reset
32
FBA COMM SW VER
ACS355:
FBA CPI FW REV
ACSM1:
FBA COMM SW VER
ACS850:
FBA comm sw ver
ACS880/ACS580:
FBA comm SW ver
Description
Read-only. Displays the drive type code of
the fieldbus adapter module mapping file
stored in the memory of the drive.
Drive type code of the fieldbus adapter
module mapping file
Read-only. Displays the fieldbus adapter
module mapping file revision stored in the
memory of the drive in decimal format.
Mapping file revision
Read-only. Displays the status of the fieldbus
adapter module communication.
Note: The value names may vary by drive.
Adapter is not configured.
Adapter is initializing.
Time-out has occurred in the communication
between the adapter and the drive.
Adapter configuration error: The major or
minor revision code of the common program
revision in the fieldbus adapter module is not
the revision required by the module or
mapping file upload has failed more than
three times.
Adapter is off-line.
Adapter is on-line.
Adapter is performing a hardware reset.
Read-only. Displays the common program
revision of the adapter module.
Common program revision of the adapter
module
Update notice
Default
N/A
N/A
0 = Idle
OR
4 = Off-line
N/A